IR-20 non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA). It can measure from 0 ℃ to maximum 400℃ in the distance of 10:1 D:S (Distance to Spot). Emissivity is 0.95 (fixed).
[ Applications ] |
Plastics, Fluids, Rubber, Coated components, Asphalt, Wood, Paper, Ceramics, Textiles, Glass, Food etc. |
|
[ Specification ] |
|
|
Measurement Range |
0~400℃ |
Device |
Thermopile |
Accuracy |
±1% / full scale |
Repeatability |
±1% of reading |
Distance : Spot |
10:1 |
Optical spectrum wave |
8~14㎛ |
Responsive Time |
500msec or below |
Emissivity |
0.95 (fixed) |
Analog Output |
4~20mA, 1~5V(option) |
Power |
DC 12~24V(Max 50mA) |
Ambient temperature(no water cooling) |
0~70℃ |
Temperature Resolution |
0.1℃ |
Warm up Period |
1 to 2 minutes |
Operating Relative Humidity |
5~90% |
Operating Ambient Temperature |
-30~85℃ |
Waterproof |
IP65,NEMA 4 |
Dimensions |
Ø36 ×110.5(L) |
Signal Cable |
2 wire shield type |
Housing material |
Aluminum Alloy |
Weight |
160g |
Cable length |
3m(standard), other(option) |
|
|
|
[ Code Number IR-20-□-□-□ ] |
|
|
Model |
Description |
IR-20 |
|
Code A |
Temperature Range |
1 |
0~200℃ |
2 |
0~400℃ |
Z |
Other |
Code B |
Output |
M |
DC 4~20mA |
N |
Voltage Output(1~5V) |
V |
Type K Thermocouple Output |
Z |
Other |
Code C |
Cable Length |
1 |
3M |
Z |
Other |
|
|
|
[Optical field of view (D:S 10:1) ] |
|
|
|