Penerangan
【SUMMARY】
Mescaline (3,4,5-Trimethoxyphenethylamine) is a naturally-occurring psychedelic alkaloid of the phenethylamine class that produces ''classical psychedelic'' effects (i.e. those of psilocybin mushrooms, mescaline, LSD, and DMT when administered. Mescaline (MES) is a derivative of phenethylamine. It is a strong hallucinogen. Can cause hallucinations, self-distortion and mind splitting, leading to depression and pupil dilation, tachycardia, excessive limbs, tremors, nausea, vomiting, and long-term use can lead to organ damage. Hallucinations can last for seven, eight or even 12 hours. The main hazard of using Mescaline is mental disorder. If users experience transient psychosis, they can also engage in violent attacks, suicide, self-harm and other behaviors.
【DIRECTIONS FOR CASSETTE USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the Test Cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface, Hold the dropper vertically and transfer 3 full drops of urine (approx. 120µl) to the specimen well of the cassette, Avoid trapping air bubbles in the specimen well
3. Wait for the color line(s) to appear.The test result should be read within 5 minutes.After 10 minutes the decision was invalid.
【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the protective cover, with the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
3. Wait for the color line(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.
【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the Test Dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the Test Dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the Test Dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
Cat. No.
|
Product Description
|
Specimen
|
Format
|
Kit Size
|
Cut-Off
|
Status
|
DMES-102
|
Mescaline (MES) Rapid Test Cassette
|
Urine
|
Cassette
|
40 T
|
100 ng/mL*, 300ng/mL
|
CE
|
DMES-114
|
Mescaline (MES) Rapid Test Panel
|
Urine
|
Panel
|
40 T
|
CE
|
DMES-101
|
Mescaline (MES) Rapid Test Dipstick
|
Urine
|
Dipstick
|
50 T
|
CE
|
Lebih maklumat tentang Setia Scientific Solution