Lysergic Acid Diethylamide (LSD) Rapid Test Panel - Powder

Lysergic Acid Diethylamide (LSD) Rapid Test Panel - Powder

Kategori: JusChek Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di setiascientific.com

Penerangan

【SUMMARY】

Lysergic acid diethylamide (LSD) is a white powder or a clear, colorless liquid. LSD is manufactured from lysergic acid which occurs naturally in the ergot fungus that grows on wheat and rye. It is a Schedule I controlled substance, available in liquid, powder, tablet (microdots), and capsule form. LSD is recreationally used as a hallucinogen for its ability to alter human perception and mood. LSD is primarily used by oral administration, but can be inhaled, injected, and transdermally applied. LSD is a non-selective 5-HT agonist, may exert its hallucinogenic effect by interacting with 5-HT 2Areceptors as a partial agonist and modulating the NMDA receptor-mediated sensory, perceptual, affective and cognitive processes. LSD mimics 5-HT at 5-HT 1A receptors, producing a marked slowing of the firing rate of serotonergic neurons. LSD has a plasma half-life of 2.5-4 hours. Metabolites of LSD include N-desmethyl-LSD, hydroxy-LSD, 2-oxo-LSD, and 2-oxo-3-hydroxy-LSD .These metabolites are all inactive. LSD use can typically be detected in urine for periods of 2-5 days.The Tramadol contained within the LSD Rapid Test Panel yields a positive result when the LSD concentration exceeds 20ng/ml.
 

【DIRECTIONS FOR USE】
Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1.Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer.
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.


FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DLS-X14

Lysergic Acid Diethylamide (LSD) Rapid Test Panel

Powder

Panel

25 T

20 ng/mL

CE


Lebih maklumat tentang Setia Scientific Solution
Setia Scientific Solution
Setia Scientific Solution Medical Supplies Kuala Lumpur (KL), Laboratory Instruments Supply Selangor, Diagnostic Test Kits Supplier Malaysia ~ Setia Scientific Solution