Tenamfetamine (MDA) Rapid Test Panel - Powder

Tenamfetamine (MDA) Rapid Test Panel - Powder

Kategori: JusChek Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di setiascientific.com

Penerangan

【SUMMARY】

3,4-Methylenedioxyamphetamine (MDA), also known as tenamfetamine (INN), or with the street name ''Sally'' or ''Sass'' or ''Sass-a-frass'', is a psychedelic and entactogenic drug of the
phenethylamine and amphetamine chemical classes. It is mainly used as a recreational drug, an entheogen, and a tool in use to supplement various types of practices for transcendence, including in meditation, psychonautics, and as an agent in psychedelic psychotherapy. It was first synthesized by G. Mannish and W. Jacobson in 1910. There are about 20 different synthetic routes described in the literature for its preparation.
The(±) 3,4-MethylenedioxyAmphetamine contained within the MDA Rapid Test Panel yields a positive result when the MDA concentration exceeds 500ng/ml.
 

【DIRECTIONS FOR USE】
Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1.Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer.
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.


FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DMDA-X14

Tenamfetamine (MDA) Rapid Test Panel

Powder

Panel

25 T

500 ng/mL

CE


Lebih maklumat tentang Setia Scientific Solution
Setia Scientific Solution
Setia Scientific Solution Medical Supplies Kuala Lumpur (KL), Laboratory Instruments Supply Selangor, Diagnostic Test Kits Supplier Malaysia ~ Setia Scientific Solution