Oxycodone (OXY) Rapid Test Panel - Powder

Oxycodone (OXY) Rapid Test Panel - Powder

Kategori: JusChek Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di setiascientific.com

Penerangan

【SUMMARY】

Oxycodone is a semi-synthetic opioid with a structural similarity to codeine. The drug is manufactured by modifying thebaine, an alkaloid found in the opium poppy. Oxycodone, like all opiate agonists, provides pain relief by acting on opioid receptors in the spinal cord, brain, and possibly directly in the affected tissues. Oxycodone is prescribed for the relief of moderate to high pain under the well-known pharmaceutical trade names of OxyContin®, Tylox®, Percodan® and Percocet®. While Tylox®, Percodan® and Percocet® contain only small doses of oxycodone hydrochloride combined with other analgesics such as acetaminophen or aspirin, OxyContin consists solely of oxycodone hydrochloride in a time-release form.
The Oxycodone contained within the OXY Rapid Test Panel yields a positive result when the OXY concentration exceeds 100ng/ml.
 
【DIRECTIONS FOR USE】
Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1. Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer.
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 
FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DOX-X14

Oxycodone (OXY) Rapid Test Panel

Powder

Panel

25 T

100 ng/mL

CE


Lebih maklumat tentang Setia Scientific Solution
Setia Scientific Solution
Setia Scientific Solution Medical Supplies Kuala Lumpur (KL), Laboratory Instruments Supply Selangor, Diagnostic Test Kits Supplier Malaysia ~ Setia Scientific Solution