Mechanical design: Solid shaft face mount flange 10 mm x 19 mm
Communication interface: PROFIBUS DP, DPV0
Connection type: Connection adapter for PROFIBUS
Programming interface: Over PLC-Engineering-Tool
Performance
Max. resolution (number of steps per revolution x number of revolutions)
13 bit x 13 bit (8,192 x 8,192)
Maximum permissible resolution: 25 bit (12 bit singleturn x 13 bit multiturn or 13 bit singleturn x 12 bit multiturn).
Error limits G
0.25° 1)
Repeatability standard deviation σr
0.1° 2)
1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.
2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.
Sensorik Automation Sdn BhdSICK Sensor, Qlight Malaysia, Cable ID printer Johor Bahru (JB), Meanwell Power Supply, Hot Marker Tubing Supplier ~ Sensorik Automation Sdn Bhd