Specifications
Heating |
Forced Air Convection |
|
Dual heating chamber system |
Temp. Range |
ambient + 10°C ~ 250°C |
Accuracy |
± 0.3°C at 120°C (JSOF-250T) |
Uniformity |
± 1.5°C at 120°C (JSOF-250T) |
Control |
Microprocessor PID Control Auto START / STOP Timer |
Sensor |
Class A Pt-100 Ω Sensor |
Safety |
Over-Temperature Cut-Off |
|
Over Current Cut-Off |
Material |
Body - Epoxy Powder Coated Steel |
|
Chamber – Stainless Steel 304 |
|
Insulation – 50mm thick woven mineral wool |
|
Shelf -including stainless steel wire shelf |
|
optional perforated stainless steel shelf |
Electric |
220±10% VAC 50/60Hz 1-Phase |
Plug config. |
CEE 7/7 Schuko or BS 1363 or 30 AMP |
Models
Art No. |
||||
Chamber Volume |
250 L |
372 L |
655 L |
|
Dimensions |
Inner |
500 x 500 x 1000 |
610 x 610 x 1000 |
710 x 710 x 1300 |
W x D x H mm |
Outer |
895 x 675 x 1360 |
1050 x 785 x 1360 |
1105 x 885 x 1660 |
|
Window |
W150 x H460 |
W150 x H460 |
W150 x H615 |
Temperature Range |
ambient +10°C to 250°C |
|||
Accuracy at 120°C |
± 0.3°C |
± 0.3°C |
± 0.3°C |
|
Uniformity at 120°C |
± 1.5°C |
± 2.0°C |
± 3.0°C |
|
Heat up time to 120°C |
10 min. |
15 min. |
15 min. |
|
No. of Shelves / Max. No. |
3 / 36 |
4 / 36 |
6 / 48 |
|
No. of Ventilation damper |
1 |
|||
Heater Capacity |
2 x 1.5 kW |
2 x 1.7 kW |
2 x 2.5 kW |
|
Power Rating |
13.8 Amp |
15.6 Amp |
22.9 Amp |
|
Power Plug |
CEE 7/7 Schuko |
30 AMP |
30 AMP |