Connection type Detail: Cable with plug M12, 5-pin
Length of cable: 0.2 m
Safe series connection: With Flexi Loop (with diagnostics)
Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs)
Features
System part
Sensor and actuator
Sensor principle
Transponder
Number of safe outputs
2
Auxiliary contact (AUX)
1 (Switching behavior complementary to OSSDs)
Safe switch on distance Sao
10 mm (–30 °C ... +70 °C) 1)
Safe switch off distance Sar
25 mm 1)
Active sensor surfaces
3
Actuation directions
5
Coding
Uniquely coded
1) Values apply for the frontal alignment of the sensor to the actuator. A detailed display of the alignment options and values can be found in the operating instructions.
Technical drawings
Dimensional drawing Sensor with cable and male connector
Dimensional drawing ''Standard'' actuator
Response range ''Standard'' actuator, active front sensor surface
Response range ''Standard'' actuator, active side sensor surface
Connection diagram
Connection single sensor
Series connection with Flexi Loop (with diagnostics)
Connection diagram STR1 transponder safety switch to RLY3-OSSD2 safety relay
Connection diagram Parallel connection of two STR1 transponder safety switches to a Flexi Classic safety controller
Sensorik Automation Sdn BhdSICK Sensor, Qlight Malaysia, Cable ID printer Johor Bahru (JB), Meanwell Power Supply, Hot Marker Tubing Supplier ~ Sensorik Automation Sdn Bhd