Agilent / Varian PVG-500S Pirani Gauge

Agilent / Varian PVG-500S Pirani Gauge

Kategori: Agilent / Varian Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di hexoind.com

Penerangan

Active Gauges

PVG-500S Pirani Gauge

 

The Agilent PVG-500 / 500S(tungsten) / 502S(nickel) series of Pirani gauges provides the ultimate combination of state-of-art technology and ruggedness within a compact design. The PVG-500 series utilizes the most advanced digital Pirani technology combined with a stainless steel sensor design to meet the various needs of the market today.

PVG500KF16RS Replacement sensor, PVG-500 Pirani gauge, tungsten filaments, KF17
PVG500KF16 PVG-500 Pirani gauge, KF17
PVG500KF16S PVG-500 Pirani gauge, tungsten filaments, with setpoints, KF17

 
Features
Specifications

Technical Specifications

Measurement range
(Air, O2, CO, N2)
5 x 10-4 to 1000 mbar (3.75 x 10-4 to 750 Torr)
Accuracy (N2) Units
% of reading + 15% 1 x 10-3 to 100 mbar (1 x 10-3 to 75 Torr)
+ 50% 5 x 10-4 to 1 x 10-3 mbar (3.75 x 10-4 to 1 x 10-3 Torr)
+ 50% 100 to 1000 mbar (75 to 750 Torr)
Repeatability (Air) 1 x 10-3 to 100 mbar (1 x 10-3 to 75 Torr) – % of reading 􏰀+2%
Output signal (measurement signal) Voltage range Measurement range
0 to 10.3 V 1.9 to 10.0 V
Voltage vs. pressure 1.286 V/decade, logarithmic
Error signal 0 to 0.5 V (filament rupture)
Minimum loaded impedance 10 kΩ, short-circuit proof
Response time 80 ms
Adjustment One tactile switch for both ATM and HV adjustment
Identification gauge 27 kΩ, referenced to supply common
Setpoint (2)   PVG-500 PVG-500S, PVG-502S
 Setting range None 2 x 10-3 to 500 mbar (1.5 x 10-3 to 375 Torr)
Hysteresis 10% above lower threshold % of reading
Relay contact 30 VDC / 0.5 ADC floating
Switching time <20 ms
Supply voltage At gauge Ripple Power consumption
14 to 30 VDC ≤1 Vpp ≤1 W
Electrical connection FCC 68/RJ45 appliance connector, 8 poles, male
Sensor cable 8 poles plus shielding
Cable length ≤ 100 meter (330 ft)
Materials exposed to vacuum Glass, Ni, NiFe, tungsten (tungsten version)
Admissible temperature Operation Storage Vacuum Connection
5 to 60 °C –20 to +65 °C 80 °C


Outline Drawing
PVG-500 Series Pirani Gauge Outline Drawing
 
Literature

Active Gauges and Controllers Brochures

This brochure contains information comparing select gauges and controllers based on your application
( https://cdn1.npcdn.net/userfiles/21330/download/1599128069_310475637543a5b9823563a6e0025b7d/Active_Gauges_and_Controllers_Brochure.pdf )



NEW PVG-500 / PVG-500S/PVG-502S Active Gauges Data Sheet

An overview of the PVG-500, PVG-500S, and PVG-502S Active Gauges
( https://cdn1.npcdn.net/userfiles/21330/download/1599229199_bcf7ded7c93029db645df2402dd85bd9/PVG_Active_Gauges_DS.pdf )





 

Lebih maklumat tentang Hexo Industries (M) Sdn Bhd
Hexo Industries (M) Sdn Bhd
Hexo Industries (M) Sdn Bhd Measuring Instruments Supplier Malaysia, Leak Detection Systems Supply Penang, Power Tools Supplies Singapore, Indonesia ~ Hexo Industries (M) Sdn Bhd