General Specification Physical |
|
---|---|
Dimensions (hxwxd) | 280 x 230 x 130 mm |
Weight | 1.7 kg including sensor and 10 metres of cable |
Protection Class |
Electronics: IP54 Sensor: IP68 |
Enclosure Material | Dark Blue Nylon |
Cable Length | 10 metres standard, 15 metres maximum |
Electrical | |
Power Supply | 9V Battery (PP3) |
Battery Life | 6 months typical use |
Environmental Data | |
Operating Temperature | 0 to 40ºC, limited by the risk of ice formation interfering with the measurement |
Storage Temperature | -20 to 60ºC |
Location | Indoor/Outdoor |
User Interface | |
Display | Front Panel LED - 'ON' in Sludge |
Audible Output |
Short Tone in Water Long Tone in Sludge |
Sensor Specification Measurement Characteristics |
|
---|---|
Principal of Operation | Light Attenuation |
Wavelength | 960 nm Infrared |
Accuracy | +/- 1 cm of interface |
Resolution | Standard cable markings every 1.0 metres |
Units of Measurement | metres |
Response Time | 0.5 seconds |
Sensor Selection | |
IR100 |
Range: 0-200 mg/l Optical Path: 100 mm Special Application Only |
IR40 |
Range: 0-1,500 mg/l Optical Path: 40 mm Wastewater Treatment - Final Settlement and Humus Tanks Drinking Water Treatment - Clarifers |
IR15 |
Range: 0-10,000 mg/l Optical Path: 15 mm Wastewater Treatment - Primary Settlement Tanks Drinking Water Treatment - Picket Fence Thickeners |
IR8 |
Range: 0-30,000 mg/l Optical Path: 8 mm Wastewater Treatment - Picket Fence Thickeners |