CM VALVES, INTERMEDIATES-- CM ELPN

CM VALVES, INTERMEDIATES-- CM ELPN

Kategori: VALVE ISLANDS & FIELDBUS Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di ipneulic.com.my

Penerangan

CM elpn 5/2 bist. , ø4 single sol.man. ctrl,24 VDC MACH 11
CM elpn 5/2 single sol., ø4 single sol.man. ctrl,24 VDC MACH 11

Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 8 / 33
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

CM elpn 5/2 bist. , ø4 bist. man. ctrl,24 VDC MACH 11
CM elpn 5/2 single sol., ø4 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 20 / 20
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

CM elpn 5/3 CC, single sol., ø4 single sol.man. ctrl,24 VDC MACH 11
CM elpn 5/3 CC, single sol., ø4 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 20 / 20
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

CM elpn n°2 3/2 NC, ø4 single sol.man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2 NC, ø4 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

CM elpn n°2 3/2 NO, ø4 bist. man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2 NO, ø4 single sol.man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

CM elpn n°2 3/2, 1 NO 1 NC, ø4 single sol.man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2, 1 NO 1 NC, ø4 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

CM elpn 5/2 bist. , ø6 single sol.man. ctrl,24 VDC MACH 11
CM elpn 5/2 single sol., ø6 single sol.man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 6
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 8 / 33
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

CM elpn 5/2 bist. , ø6 bist. man. ctrl,24 VDC MACH 11
CM elpn 5/2 single sol., ø6 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 6
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 20 / 20
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

CM elpn 5/3 CC, single sol., ø6 single sol.man. ctrl,24 VDC MACH 11
CM elpn 5/3 CC, single sol., ø6 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 6
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 20 / 20
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

CM elpn n°2 3/2 NC, ø6 single sol.man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2 NC, ø6 bist. man. ctrl,24 VDC
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 6
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

CM elpn n°2 3/2 NO, ø6 bist. man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2 NO, ø6 single sol.man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 6
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

CM elpn n°2 3/2, 1 NO 1 NC, ø6 single sol.man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2, 1 NO 1 NC, ø6 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 6
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

CM elpn 5/2 bist. , ø8 single sol.man. ctrl,24 VDC MACH 11
CM elpn 5/2 single sol., ø8 single sol.man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 8
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 33
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

CM elpn 5/2 bist. , ø8 bist. man. ctrl,24 VDC MACH 11
CM elpn 5/2 single sol., ø8 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 8
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

CM elpn 5/3 CC, single sol., ø8 single sol.man. ctrl,24 VDC MACH 11
CM elpn 5/3 CC, single sol., ø8 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 8
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

CM elpn n°2 3/2 NC, ø8 single sol.man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2 NC, ø8 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 8
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

CM elpn n°2 3/2 NO, ø8 bist. man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2 NO, ø8 single sol.man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 8
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

CM elpn n°2 3/2, 1 NO 1 NC, ø8 single sol.man. ctrl,24 VDC MACH 11
CM elpn n°2 3/2, 1 NO 1 NC, ø8 bist. man. ctrl,24 VDC MACH 11
Control PNP or NPN
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 32
Maximum number of valves 32
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 8
Pliot pressure range 3÷7
Power 0.9 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

Lebih maklumat tentang I Pneulic Industries Supply Sdn Bhd
I Pneulic Industries Supply Sdn Bhd
I Pneulic Industries Supply Sdn Bhd Hydraulic Equipment Supplier Malaysia, Pneumatic System, Industrial Hoses Supplies Perak ~ I Pneulic Industries Supply Sdn Bhd