Digital Thermometer
415M | - | □ | - | □ | - | □ | - | □ |
① | ② | ③ | ④ |
Code | Type *1 | Measuring Range | Display Range | Accuracy *2 |
---|---|---|---|---|
T C | R | 100 to 1700°C | -50 to 1750°C | ±(0.3% of rdg + 1°C) |
K | -100 to 1300°C | -199 to 1350°C | ||
E | -130 to 1000°C | -199 to 1050°C | ||
J | -140 to 1200°C | -199 to 1250°C | ||
T | -199 to 400°C | -199 to 420°C | ||
B | 600 to 1800°C | -20 to 1810°C | ||
N | -100 to 1300°C | -199 to 1350°C |
*1 There will be °C display of K type T/C during shipment. | |
*2 Accuracy | : Defined in the measuring range, at 23 ± 5°C, 45 to 75% RH. |
Temperature coefficient | : ±300 ppm/°C (operating temp.: 0 to 50°C) |
Cold junction compensation | : ±1°C (operating temp.: 0 to 50°C) |
Calibration is made with standard thermo-electricity input (mV) in accordance with JIS C-1602. |
Code | Type *3 | Measuring Range | Display Range | Accuracy *4 |
---|---|---|---|---|
PT | Pt100Ω | -199.9 to 600.0°C | -199.9 to 650.0°C | ±(0.2% ofrdg + 0.3°C) |
JPt100Ω |
*3 There will be Pt100Ω and °C setting display during shipment. | |
*4 Accuracy | : Defined in the measuring range, at 23 ± 5°C, 45 to 75% RH. |
Temperature coefficient | : ±200 ppm/°C (operating temp.: 0 to 50°C) |
Calibration is made with standard resistance values in accordance with JIS C-1604. |
Code | Specifications | Output Impedance | Allowable Load Resistance |
---|---|---|---|
Blank | For display only | ||
03 | Analog output DC 0 to 1 V | Less than 0.1 Ω | More than 1 kΩ |
04 | Analog output DC 0 to 5 V | Less than 0.1 Ω | More than 5 kΩ |
05 | Analog output DC 0 to 10 V | Less than 0.1 Ω | More than 10 kΩ |
09 | Analog output DC 1 to 5 V | Less than 0.1 Ω | More than 5 kΩ |
23 | Analog output DC 0 to 1 mA | More than 5 MΩ | 0 to 5 kΩ |
29 | Analog output DC 4 to 20 mA | More than 5 MΩ | 0 to 600 Ω |
BP | BCD output (TTL level: positive logic) |
---|---|
BN | BCD output (TTL level: negative logic) |
DN | BCD output (Transistor output sink type) |
RY | Dual setting comparator (Relay contact output) |
TN | Dual setting comparator (Open collector output NPN) |
TP | Dual setting comparator (Open collector output PNP) |
Display | Red or green LED (character height 15 mm) with zero-suppress function. |
---|---|
Mode change-over | 1 digit, red or green LED (character height: 8 mm) |
Over-range display | When exceeded the displayable range, the minimum or maximum value of the displayable range flashes. |
Open circuit of input |
Thermocouple input: Flashs with the minimum value of the display range. Resistance thermo bulb input: Flashs with the maximum value of the display range. |
Resolution |
Thermocouple: 1°C Resistance Thermometer: 0.1°C |
External resistance |
Thermocouple input: Less than 500 Ω Resistance thermo bulb input: Less than 5 Ω/lead wire |
Overload | DC ±10 V |
Sampling rate | Approx. 2.5 times/sec. |
Input configuration | Single ended, floating input |
A/D conversion | ⊿-∑ conversion system |
Noise rejection |
Normal mode (NMR) More than 50 dB Common mode (CMR) More than 110 dB Power source line mixing noise 1000 V |
Hold function |
Holds measured data, peak/bottom memory value and data output (option). (Not isolated from the input) |
Peak/bottom memory function | Display of maximum or minimum value is selectable with the front panel switch. |
Withstand voltage |
Between input terminals and each output COM: AC 500 V for 1min. Between input terminals and relay output: AC 1000 V for 1min. Between input/output terminals and power source terminals: AC 1500 V for 1min. (For DC power source: 1000 V AC for 1min.) Between power source terminals and external case: AC 1500 V for 1min. |
Insulation resistance | DC 500 V, More than 100 MΩ |
Operating temperature | 0 to 50°C |
Protection degree | Operation section on the front IP65, Rear case IP20, Terminals section IP00 |
Weight | Approx. 200 g |