TSURUGA MODEL 7522

TSURUGA MODEL 7522

Kategori: Transducer Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di improtechonline.com

Penerangan

Thermocouple Transducer

Isolated Thermocouple Signal Transducer

Model Designation

7522 - - -
       
① Input Signal
Code Input
1E R 0 to 1400°C
* Accuracy guarantee range :400 to 1400°C
28 K 0 to 300°C
29 K 0 to 400°C
2A K 0 to 500°C
2B K 0 to 600°C
2C K 0 to 1000°C
2D K 0 to 1200°C
37 E 0 to 200°C
45 J 0 to 100°C
46 J 0 to 150°C
47 J 0 to 200°C
49 J 0 to 400°C
55 T 0 to 100°C
56 T 0 to 150°C
57 T 0 to 200°C
58 T 0 to 300°C
② Output Signal
Code Output
01 DC 0 to 10 mV
02 DC 0 to 100 mV
03 DC 0 to 1 V
04 DC 0 to 5 V
05 DC 0 to 10 V
09 DC 1 to 5 V
00 Except above DC voltage output
(More than 10 mV less than 10 V)
13 DC ± 1 V
14 DC ± 5 V
10 Except above DC ± voltage output
(More than ± 10 mV less than ± 10 V)
23 DC 0 to 1 mA
29 DC 4 to 20 mA
20 Except above DC current output
(More than 100 µA less than 20mA)
③ Power Supply Voltage
Code Power
3 AC 100/110 V
5 AC 200/220 V
9 DC 24 V

Output Specifications

Output Signal Output Impedance Tolerable Load Resistance
DC 0 to 10 mV Approx. 10 Ω More than 10 kΩ
DC 0 to 100 mV Approx. 100 Ω More than 100 kΩ
DC 0 to 1 V Less than 0.1 Ω More than 100 Ω
DC 0 to 5 V More than 500 Ω
DC 0 to 10 V More than 1 kΩ
DC 1 to 5 V More than 500 Ω
DC ± 1 V
DC ± 5 V More than 2.5 kΩ
DC 0 to 1 mA More than 5 MΩ 0 to 12 kΩ (During DC Power 0 to 10 kΩ)
DC 4 to 20 mA 0 to 600Ω (During DC Power 0 to 500 Ω)

General Specifications

Input Selectable thermocouple
Tolerable external resistance: Less than 500 Ω
Allowance ±0.3% of SPAN at 23°C
Cold junction compensation accuracy sensor K, E, J or T: Less than ± 0.5°C
sensor R: Less than ± 1°C
(under the condition of 0 to 40°C)
Response Less than 0.5s (0→90%)
Temperature coefficient 200 ppm/°C
Output adjustment range ZERO:More than ± 3% of SPAN
SPAN:More than ± 5% of SPAN
Insulation resistance Between Input terminals, Output terminals and Power supply terminals : DC 500 V More than 100 MΩ
Withstand voltage Between Input terminals and Power supply terminals: AC 1500 V 1min. (During DC Power: AC 1000 V 1min.)
Between Input terminals and Output terminals: AC 1500 V 1min. (During DC Power: AC 1000 V 1min.)
Between all terminals and external case: AC 1500 V 1min.
Power supply voltage
AC 100/110 V ± 10% 50/60 Hz : Less than 3 VA
AC 200/220 V ± 10%  50/60 Hz : Less than 3 VA
DC 24 V ± 10% : Less than 70 mA
Operating temperature -5 to 55°C
Storage temperature -20 to 70°C
Weight
Body:
Approx. 400 g (AC Power Supply)
Approx. 250 g (DC Power Supply)
Socket:
Approx. 70 g

Lebih maklumat tentang TECH IMPRO AUTOMATION SOLUTION SDN BHD
TECH IMPRO AUTOMATION SOLUTION SDN BHD
TECH IMPRO AUTOMATION SOLUTION SDN BHD Industrial Automation Supplier Malaysia, Flow Meter Supply Penang, Pressure Transmitter Supplies Butterworth ~ TECH IMPRO AUTOMATION SOLUTION SDN BHD