HIOKI - Multi-range EC Meters
Brand: Hioki
Model: HI8633 & HI8733
 
The HI8633 and HI8733 conductivity meters have been designed for use in areas of production and quality control. These meters utilize four-ring potentiometric probes that o&er greater versatility over typical amperometric designs. These rugged probes are made of PVC and are ideal for indoor as well as outdoor measurements. HI8733’s conductivity measurements can be automatically temperature compensated by using the HI76302W probe with the built-in temperature sensor. Temperature compensation for HI8633 is performed by manual adjustment.
 
Specifications:

Model HI8633 HI8733
Range 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm
0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
0.0 to 199.9 μS/cm; 0 to 1999 μS/cm
0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
Resolution 0.1 μS/cm; 1 μS/cm
0.01 mS/cm; 0.1 mS/cm
0.1 μS/cm; 1 μS/cm
0.01 mS/cm; 0.1 mS/cm
Accuracy  (@25°C/77°F) ±1% F.S. (excluding probe error) ±1% F.S. (excluding probe error)
Calibration manual, one-point through EC knob manual, one-point through EC knob
Temperature Compensation manual, 0 to 50°C (32 to 122°F)
with β  = 2%/°C
automatic, 0 to 50°C (32 to 122°F)
with β  adjustable from 0 to 2.5%/°C
Probe HI76301D four ring conductivity
probe with DIN connector and
1 m (3.3’) cable (included)
HI76302W four-ring conductivity
probe with internal temperature
sensor, DIN connector and 1 m (3.3’)
cable (included)
Battery Type/ Life 9V / approximately 100 hours of
continuous use
9V / approximately 100 hours of
continuous use
Environment 0 to 50°C (32 to 122°F); RH max 100% 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’) 145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)
Weight 230 g (8.1 oz.) 230 g (8.1 oz.)
Order Information HI8633 is supplied with HI76301D conductivity probe, 12880 μS/cm HI70030 calibration solution sachets (5), battery, instructions and rugged carrying case.
HI8733 is supplied with HI76302W conductivity probe, 12880 μS/cm HI70030
calibration solution sachets (5), battery, instructions and rugged carrying case.

Lebih maklumat tentang Carlssoon Technologies (Malaysia) Sdn Bhd
Carlssoon Technologies (Malaysia) Sdn Bhd
Carlssoon Technologies (Malaysia) Sdn Bhd Testing Equipment Supplier Melaka, Measuring Instrument Supply Malaysia, Lab Supplies Ayer Keroh ~ Carlssoon Technologies (Malaysia) Sdn Bhd