Output Signal |
4/20 mA, 2-wire / V = 10.5-55 Vdc
4/20 mA + HART, 2-wire / V = 16.5-55 Vdc
1/5 Vdc, 3-wire / V = 10.5-55 Vdc
Modbus, 4-wire / V = 9-30 Vdc |
LCD Display |
LCD display (standard) or without LCD display (optional) |
Accuracy |
0.2% URL standard, 0.5% optional |
Stability |
0.1% per year |
Temperature Range |
Working: -40/85°C (with display -20/70°C), -40/185°F (with display -4/158°F)
Storage: -40/110°C (with display -40/85°C), -40/230°F (with display -40/185°F)
Media: silicone oil filling: -40/120°C (-40/248°F) |
Working Humidity |
5-100% at 40°C (104°F) |
Pressure Connection |
1/4” or 1/2” NPTM or F, 1/4” or 1/2” GM (large 10mm orifice) |
Housing |
Rugged die-cast aluminum housing, painted blue |
Wetted Parts |
316L SS |
Overload Pressure |
1.5 x rated pressure |
Power Consumption |
</- 500 mW @ 24 VDC, 20.8 mA |
Vibration |
20g, 20Hz…5kHz
According to GB/T 1827.3 / IEC 61298-3 tests, <0.1% URL |
Shock |
20g, 20Hz…5kHz |
Available Pressure Units |
kPa, Mpa, bar, psi, mmHg, mmH2O, mH2O, inH2O, ftH2O, inHg, mHg, TORR, mbar, g/cm2,
kg/cm2, Pa, ATM |
Available Temperature Units |
Celsius, Fahrenheit |
Protection Class |
EMI, ESD, RFI, reverse polarity protected |
Approvals |
CSA, for USA & Canada
• Class I, Division 1, Group A,B,C and D T6 | Class II, Division 1 Group E, F and G T80oC | Class III
Intertek, for USA & Canada
• Class I, Zone 0 A Ex ia IIC T6 Gb | Class I, Division 1, Group A-D, T6 | – 40oC to 60oC |
Protection Class |
IP66 / IP67 |
Weight |
2.9 lbs (1.3 kg) |
Operational Life |
100 million cycles |