APPLICATIONS:
DESCRIPTION & FEATURES:
Output Signal | Standard 2-wire: 4-20 mA / Vs = 12-36 Vdc |
Accuracy |
<±0.35% FSO BFSL Optional nominal pressure > 5 psi: <±0.25% FSO BFSL |
Permissible Load | Rmax = [(Vs – Vs min) / 0.02] Ohm |
Influence Effects |
Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
Long-term Stability | <±0.1% FSO/yr |
Response Time | <10 ms |
Permissible Temperatures |
Medium: 14°F to 158°F (-10°C to 70°C) Storage: -13°F to 158°F (-25°C to 70°C) |
Reverse Polarity Protection | No damage. No function. |
Electromagnetic Compatibility | Emission and immunity according to EN 61326 |
Electrical Connection | Cable with sheath material*: PVC grey, PUR black, FEP black |
Housing | 316Ti SS |
Seals | FKM / EPDM |
Diaphragm | 316L SS |
Weight | 100 g (without cable) |
Current Consumption | 25 mA max |
Connecting Cables |
Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m |
Enclosure Rating | NEMA 6P / IP68 |