Output Signal |
Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc
Optional 3-wire: 0-20 mA / Vs = 14-30 Vdc
0-10 V / Vs = 14-30 Vdc
|
Accuracy |
≤±0.5% FSO |
Permissible Load |
Current 2-wire: Rmax = [(Vs – Vs min) / 0.02] Ohm
Current 3-wire: Rmax = 500 Ohm
Voltage 3-wire: Rmin = 10 kOhm
|
Influence Effects |
Supply: 0.05% FSO / 10 V
Load: 0.05% FSO / kOhm
|
Response Time |
≤10 ms |
Thermal Error |
≤±0.2% FSO / 10K |
Permissible Temperatures |
Medium: 14°F to 158°F (-10°C to 70°C)
Storage: -13°F to 158°F (-25°C to 70°C)
|
Short Circuit Protection |
Permanent |
Reverse Polarity Protection |
No damage. No function. |
Electromagnetic Protection |
Emission and immunity according to EN 61326 |
Connecting Cables |
Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m
Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m
|
Electrical Connection |
Cable with sheath material: PVC grey, PUR black, FEP black |
Pollution Degree |
4, electrical equipment for outdoor use |
Housing |
316L SS |
Seals |
FKM / EPDM |
Diaphragm |
Ceramic AI2O3 96% |
Protection Cap |
POM |
Current Consumption |
Current: 25 mA max
Voltage: 7 mA max
|
Weight |
250 g (without cable) |
Enclosure Rating |
NEMA 6P / IP68 |
CE Conformity |
EMC directive: 2004/108/EC |