Thrust force and Torque are measured simultaneously.
Rated Output is adjusted at ±5V
in both Mz and Fz direction.
Just connect a sensor and apply 24V to it, then adjusted voltage will be outputted simultaneously.
Any calibration settings are not required.
Model | Sensor : URT-20-5K Amplifier : FS200 |
---|---|
Rated capacity | Mz : ±20Nm Fz : 5kN |
Power supply voltage | DC24V±15% |
Consumption current | 150mA or less |
Load signal output | Mz, Fz : ±5V |
Load resistance | 2kΩ or more |
Response | 2kHz |
I/O signal |
Input: Auto zero command Output: Auto zero response |
Safe overload | Mz : 500%FS Fz : 400%FS |
Non-linearity | Mz : 0.1%FS typ. Fz : 0.5%FS |
Hysteresis | Mz : 0.1%FS typ. Fz : 0.5%FS |
Repeatability | Mz : 0.1%FS typ. Fz : 0.5%FS |
Cross talk |
Mz(20Nm) → Fz:0.05kN or less Fz(5kN) → Mz:0.2Nm or less |
Compensated temp. range | 0 to +40℃ |
Safe temp. range | -10 to +50℃ |
Temp. effect on zero | 0.1%FS/℃ |
Temp. effect on span | 0.05%FS/℃ |
Sensor material | Stainless steel |
Weight |
Sensor:Approx. 250g, Amplifier:Approx. 180g (Excluding the cable) |
*Above specifications are achieved when the sensor(URT-20-5K) is connected with the dedicated amplifier(FS200).
*Accuracy is not guaranteed in the range of Fz 0 to -5V.
Product catalogue(PDF)
|
URT-20-5K catalogue(480 KB) |
---|