With the SITRANS FC310 digital Coriolis flowmeter, you can fit more meters into less space and reduce skid size without compromising performance. The FC310 features an all-in-one design for streamlined installation, easy integration into your control system and optimal cost efficiency since you only pay for what you really need.
The complete system can be ordered for standard or hygienic use.
The FC310 flowmeter consists of a SITRANS FCS300 sensor and a SITRANS FCT010 transmitter.
Sizes
|
DN15 (½'')
DN25 (1'') DN50 (2'') DN80 (3'') DN100 (4'') DN150 (6'') |
---|---|
Accuracy
|
±0.10 % or ±0.20 % |
Repeatability
|
±0.05 %
|
Density accuracy
|
2 or 10 kg/m 3
|
Flow range
|
DN15: 8,000 kg/h (17,600 lb/h)
DN25: 35,000 kg/h (77,000 lb/h) DN50: 90,000 kg/h (198,000 lb/h) DN80: 250,000 kg/h (550,000 lb/h) DN100: 520,000 kg/h (1,146,404 lb/h) DN150: 860,000 kg/h (1,895,975 lb/h) |
Material
|
Wetted parts: 316L stainless steel, C4 (2.4610) nickel alloy or C22 (2.4602) nickel alloy
Enclosure: 304L stainless steel |
Pressure rating
|
All sizes: 100 bar (1,450 psi)
|
Temperature rating
|
All sizes: -50 … 205 °C (-58 … 400 °F) |
Sensor enclosure rating
|
IP67 (NEMA 4X)
|
Approvals
|
Hazardous: ATEX, IECEx, cCSAus |
Configuration
|
Compact or remote |
Communication
|
Modbus RS485
|
Power supply
|
DC |
Special features
|
Aerated flow filtering
|