DC Voltage range | 600.0 mV to 1000 V, 5 ranges. Basic accuracy: ±0.15% rdg. ±2 dgt. |
AC Voltage range | 6.000 V to 1000 V, 4 ranges. Frequency characteristics: 40 Hz to 1 kHz. Basic accuracy (40 Hz - 500 Hz): ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
DC + AC Voltage range | 6.000 V to 1000 V, 4 ranges. Frequency characteristics: DC, 40 Hz to 1 kHz. Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
LoZ V | 600.0 V, 1 range. Frequency characteristics: DC, 40 Hz to 1 kHz. Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges. Basic accuracy: ±0.7% rdg. ±3 dgt. |
DC Current range | 600.0 mA to 10.00 A, 3 ranges. Basic accuracy: ±0.5% rdg. ±3 dgt. |
AC Current range | 600.0 mA to 10.00 A, 3 ranges. Basic accuracy (40 Hz - 500 Hz): ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less). Frequency characteristics: 40 Hz to 1 |
AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
Capacitance range | 1.000 µF to 10.00 mF with 5 ranges. Basic accuracy: ±1.9% reading ±5 digits |
Continuity Check | Threshold ON: 25 Ω, Threshold OFF: 245 Ω. Response time: 0.5 ms or more |
Diode Test | Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less. Threshold of forward voltage: 0.15 V to 1.8 V |