Production information
Insulation Rresistance Measurement | ||||
---|---|---|---|---|
Insulation test voltage | Range | Accuracy | ||
50V | 300KΩ/3.00MΩ/30.0MΩ/300MΩ/1.00GΩ | ±(3%rdg+5dgts) (30KΩ~1.00GΩ) | ||
100V | 600KΩ/6.00MΩ/60.0MΩ/600MΩ/2.00GΩ | ±(3%rdg+5dgts) (60KΩ~2.00GΩ) | ||
250V |
1.50MΩ/15.0MΩ/150MΩ/1.50GΩ 5.0GΩ |
±(3%rdg+5dgts) (0.15MΩ~1.50GΩ) ±(10%rdg+3dgts) |
||
500V |
3.00MΩ/30.0MΩ/300MΩ/3.00GΩ 10.0GΩ |
±(3%rdg+5dgts) (0.30MΩ~3.00GΩ) ±(10%rdg+3dgts) |
||
1000V |
6.00MΩ/60.0MΩ/600MΩ/6.00GΩ 20.0GΩ |
±(3%rdg+5dgts) (0.60MΩ~6.00GΩ) ±(10%rdg+3dgts) |
AC/DC Voltage | |||
Range | Resolution | Accuracy (AC: 45~500Hz) | Protection |
60.00V/600.0V | 0.01V/0.1V | ±2%rdg+5dgts | 600Vrms |
Resistance | |||
Range | Resolution | Accuracy | Protection |
600.0Ω/6.000KΩ/60.00ΚΩ/600.0ΚΩ | 0.1Ω/0.001KΩ/0.01ΚΩ/0.1ΚΩ | 2%rdg+5dgts | 600Vrms |
Continuity | |||
Range | Resolution | Accuracy | Protection |
600.0Ω | 0.1Ω | ≦ 7Ω±1Ω | 600Vrms |
LoΩ | |||
Range | Resolution | Accuracy | |
6.00Ω/60.0Ω | 0.01Ω/0.1Ω | 2%rdg+3dgts |
Auto Power Off: Approx. 10 minutes |
Approvals: EN61010 600V CAT IV |
Electromagnetic Compatibility: EN61326-1 |
Battery: 1.5V size AA battery x 4 |
Dimensions: 206x90x51 mm |
Weight: 510g |