Carbon Monoxide |
0–5% (Accuracy ±10%) Res 0.01% |
Handset Dimensions |
7.9 x 1.8 x 3.5'' (200 x 45 x 90 mm) |
Lamda/AFR (Air Fuel Ratio) |
0.6–1.4 / 8.82:1–20.58:1 (Gasoline) |
Replacement Probe Spigot |
HHGA-14 |
Pre Programmed Fuels |
Gasoline/LPG/CNG |
AC Adaptor, Input |
100–240~ /50–60 Hz/300 Ma |
EN 61000-6-3 |
Compliant |
Screen |
Six Line Backlit LCD w/ Screen Protection |
Replacement Probe |
HHGA-9 |
Bluetooth |
Yes – Class 1 |
Auto Re-Zero |
Yes (every 30 minutes) |
Country Of Origin |
GBR |
CE Approved |
Yes |
Oxygen |
0–21% (Accuracy ±5%) Res 0.02% |
Warranty |
1 Year |
Corrected CO |
0–5% Calculation |
Sensor replacement |
Service Center Only – Crystal Lake |
Electrochemical Sensors |
Measure O2 and NO |
AC Adaptor, Output |
9 VDC/1 A |
EN 61000-6-1 |
Compliant |
Print Function |
IR emitter to HHGA-PRINTER (Optional on HHGA5C) |
Battery Life |
120 Minutes (on standby) From Full Charge |
12 V Car Charger included |
Yes |
Hydrocarbons |
0–2,000 PPM (Accuracy ±10%) Res 1 PPM |
Oxides of Nitrogen |
0–1,500 PPM (Accuracy ±10%) Res 1 PPM |
Handset Weight, lb (kg) |
2.2 (1) |
Service and Calibration |
As required – Recommend Annually |
Replacement Filters |
HHGA-11 |
Internal Memory |
Yes – Stores 100 tests (manual or automatic) |
Infra-red Sensors |
Measure CO, CO2 and HC |
Carbon Dioxide |
0–15% (Accuracy ±10%) Res 0.1% |