Genie G Ultrapure & EDI Water System produces ultrapure water (Type I water) and EDI water (Type II water) from tap water directly. It offers desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure and Type II pure water in the lab. Quality of ultrapure water and EDI water meet or exceed ASTM, CLSI, CAP, and ISO Type I water and Type II water standards, respectively.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Specifications
Feed Water Requirements |
Tap water |
Municipal water, Conductivity < 2000 μS/cm (1000 ppm) |
Operating temperature |
5 - 35 ℃ |
Feed water pressure |
1 - 6 bar (15 - 90 psi) |
Water Flow Rate |
EDI water production rate (@ 25°C) |
5, 10, 15 L/hr |
EDI water dispensing rate |
Up to 2.0 L/min |
Ultrapure water dispensing rate |
Up to 2.0 L/min |
Product Water Quality |
RO rejection |
97 to 98% ionic rejection (new RO cartridge)
> 99% organic rejection
> 99% particulates & bacteria rejection |
EDI water resistivity (@ 25°C) |
> 5 MΩ·cm (typically 10 - 16 MΩ·cm) |
EDI water TOC* |
< 30 ppb |
Ultrapure water resistivity (@ 25°C) |
18.2 MΩ·cm |
Ultrapure water TOC* |
< 2 ppb |
Particles in ultrapure water ( > 0.2 μm) |
No particles (with a 0.2 μm final filter or RephiBio filter) |
Microorganisms in ultrapure water |
< 0.01 cfu/ml (with a 0.2 μm final filter or RephiBio filter) |
Pyrogens in ultrapure water |
< 0.001 Eu/ml (with a RephiBio filter) |
RNase in ultrapure water |
< 0.5 pg/ml (with a RephiBio filter) |
DNase in ultrapure water |
<10 pg/ml (with a RephiBio filter) |
Product Water Quality Stored in Tank ( for tank recirculation models ) |
Resistivity (@25℃) |
> 1 MΩ·cm (default), adjustable |
Dimensions |
Main system dimensions (Width × depth × height) |
32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in) |
Dispenser dimensions (Width × depth × height) |
21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in) |
Weight |
20 kg |
Input Voltage |
110 - 240 VAC |
Operating Voltage |
24 VDC |
Main system power |
< 200 W |
*In the appropriate operating conditions, otherwise typically ≤5 ppb.
Features:
Design & Functions
• The system can be linked to multiple dispensers via CAN cable or wireless. “1+N” Mode.
• Automatic temperature compensation allows RO production rate stable over a wide range of temperature.
• Exceptionally consistent and predictable high purity Type II water from the best-in-class EDI (electrodeionization) module.
• Fully automated system has cleaning, rising, flush and many other functions.
• System automatically rinses a new RO membrane. Users do not need to set special rinse program for a new RO membrane.
• A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
• The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
• The chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
• Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in case of unexpected leaking.
• Tank recirculation model guarantees water quality in the tank.
Effective TOC level controlment
• Built-in 254 nm lamp kills bacteria and a 185/254 nm dual wavelength UV lamp reduces TOC level in ultrapure water.
• A tank sanitization module is equipped to effectively keep microbial growth at a lower level by LED UV light.
• On-line TOC monitor based on complete oxidation methods.
Easy Operation and Maintenance
• Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
• RFID tags ensure perfect placement of consumables and trace their performance.
• Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
• Signature verification for maintenance and service.
Cartridges and Parts
1. EDI module
• Internal EDI module removes the remaining ions, further reduces the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water.
• Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed.
• EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of the energy.
2. Cartridge
• Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
• AC Pack contains special activated carbon to remove organic impurities and free chlorines.
• Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
3. Control console
• 8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
• The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
• The console screen and dispenser screens are water drop proof. You can operate the console and dispenser with latex gloves on.
• The system has two level password protection on display menu for safety purposes.
4. Dispenser
• The volumetric function can automatically deliver the water volume you need once it is set up.
• With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
• A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
5. Final Filter
• A wide range of final filters (optional) is applicable to ensure ultrapure water without particles, bacteria or pyrogen.
6. Level sensor
• The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
• Water level and quality inside the tank can be viewed from the control console.
Main Applications
Ultrapure Water
Important and critical applications
• HPLC mobile phase preparation
• Preparation of reagent blank solution
• As sample diluents for GC, HPLC, UPLC, AA, ICP-MS and other analytical techniques
• Preparation of buffer and culture media for mammalian cell culture
• Preparation of molecular biology reagents, etc.
EDI Pure Water
Routine and non-critical applications
• Preparation of chemical bio-reagents
• Preparation of culture media
• Preparation of solution for chemical analysis such as HPLC and ICP
• Feed water to ultrapure water systems
• Feed water to medical device and equipment (clinical analyzers, Aging testers etc.)
• For serum and blood fractionation
• For ophthalmic
Order Information
• Genie G 5 Water System (RG0G005T0)
• Genie G 10 Water System (RG0G010T0)
• Genie G 15 Water System (RG0G015T0)
Lebih maklumat tentang SCIENCEGATES SDN BHD