Penerangan
Energy-Saving Simulation after replacing pressure reduction valves with Oil-Free Booster Bebicon:
1. Calculation conditions:
- DSP-55kWx4 units controlled by Multi-Controller, Operation Rate 78%
- Discharge pressure 0.7MPa, average use of compressed air is 20m³/min
Effect:
Item - Unit |
Before |
After |
Power consumption (MWh/year) |
Main Screw Compressor |
1147 |
927 |
Booster BEBICON |
0 |
40 |
Simulated Annual Power Consumption (MWh/year) |
1147 |
967 |
Specific Energy Consumption (m³/min/kW) |
0.105 |
0.124 |
CO2 Emission (t-CO2/Year) |
533 |
449 |
CO2 Reduction Rate (%) |
16 |
Specification:
Tank Mounted/ Package Type |
Tank Mount Type |
Package Type |
Model
|
OBB-1.5GP5 |
OBB-3.7G5A |
OBB-7.5G5A |
OBB-7.5HP5 |
OBB-11GP5 |
POB-3.7GP5 |
POB-7.5G5A |
POB-11G5A |
OBB-1.5GP6 |
OBB-3.7G6A |
OBB-7.5G6A |
OBB-7.5HP6 |
OBB-11GP6 |
POB-3.7GP6 |
POB-7.5G6A |
POB-11G6A |
Item - Unit |
|
|
|
|
|
|
|
|
Motor Nominal Output |
kW |
1.5 |
3.7 |
7.5 |
11 |
3.7 |
7.5 |
11 |
Suction Air Pressure |
MPa |
0-0.5 |
0.2-0.5 |
Max. Discharge Pressure |
MPa |
1.0 |
1.37 |
1.0 |
1.0 |
On-Off Control Pressure |
MPa |
0.8-1.0 |
1.18-1.37 |
0.8-1.0 |
0.8-1.0 |
Air Capacity |
L/min |
600 |
1400 |
2850 |
2500 |
4250 |
1400 |
2850 |
4250 |
Air Tank Volume |
L |
38 |
170 |
280 |
35 |
- |
Air Inlet |
- |
Rc3/4 |
Rc1 |
Rc3/4 |
Rc1 |
Air Outlet |
- |
G3/8B Stop Valve |
Rc3/4 Stop Valve |
Rc1 Stop Valve |
Rc3/4 Stop Valve |
Rc1 Stop Valve |
External Dimensions (WxDxH) |
mm |
846x447x762 |
1774x518x972 |
1774x553x958 |
1938x608x1114 |
1938x679x1113 |
850x630x1180 |
981x786x1492 |
1197x931x1513 |
Weight |
kg |
67 |
205 |
261 |
300 |
356 |
210 |
290 |
399 |
Lebih maklumat tentang SYT.INDUSTRIAL AIR TRADING & SERVICE CO.