* Supported only for USLC-100KN
Model | USLC-50KN | USLC-100KN |
---|---|---|
Rated capacity | 50 kN | 100 kN |
Rated output | Approx. 2 mV/V | |
Safe overload | 150% R.C. | |
Zero balance | ±10% R.O. | |
Non-linearity | 0.3% or less R.O. | |
Hysteresis | 0.3% or less R.O. | |
Repeatability | 0.1% or less R.O. | |
Compensated temperature range | -10 to +60℃ | |
Safe temperature range | -20 to +70℃ | |
Temperature effect on zero |
0.5% R.O/10℃ or below | |
Temperature effect on span |
0.5% R.O/10℃ or below | |
Input resistance | Approx.700 Ω | |
Output resistance | Approx.700 Ω | |
Recommended excitation voltage | 5 V | |
Maximum excitation voltage | 10 V | |
Insulation resistance (DC 50 V) |
1000 MΩ or more | |
Cable | φ2 4-conductor flexible cable (3 m) Cable end: 5 wires |
φ3.8 4-conductor flexible cable (3 m) Cable end: 5 wires |
Load cell material | Stainless steel | |
Deflection at rated | 0.08 mm | 0.07 mm |
Natural frequency | 39 kHz | 16.3 kHz |
Weight | 40 g | 210 g |
RoHS directives | 2011/65/EU (EU)2015/863 |
* Due to the characteristics of the stainless steel being used for, it is possible that it gets rusty on its surface.There is functionally no problem.