Thrust force and Torque are measured simultaneously.
Rated Output is adjusted at ±5 V
in both Mz and Fz direction.
Just connect a sensor and apply 24 V to it, then adjusted voltage will be outputted simultaneously.
Any calibration settings are not required.
Model | Sensor : URT-20-5K Amplifier : FS200 |
---|---|
Rated capacity | Mz : ±20 Nm Fz : 5 kN |
Power supply voltage | DC 24 V±15% |
Consumption current | 150 mA or less |
Load signal output | Mz, Fz : ±5 V |
Load resistance | 2 k!& or more |
Response | 2 kHz |
I/O signal | Input: Auto zero command Output: Auto zero response |
Safe overload | Mz:500% FS Fz:400% FS |
Non-linearity | Mz:0.1% FS typ., Fz:0.5% FS or less |
Hysteresis | Mz:0.1% FS typ., Fz:0.5% FS or less |
Repeatability | Mz:0.1% FS typ., Fz:0.5% FS or less |
Cross talk | Mz(20 Nm) → Fz:0.05 kN or less Fz(5 kN) → Mz:0.2 Nm or less |
Compensated temp. range | 0 to +40℃ |
Safe temp. range | -10 to +50℃ |
Temp. effect on zero | 0.1% FS/℃ or below |
Temp. effect on span | 0.05% FS/℃ or below |
Sensor material | Stainless steel |
Weight | Sensor:Approx. 250 g, Amplifier:Approx. 180 g |
*Above specifications are achieved when the sensor(URT-20-5K) is connected with the dedicated amplifier(FS200).
*Accuracy is not guaranteed in the range of Fz 0 to -5 V.
Please note that there are possibilities of individual differences in a color tone on display devices such as LEDs, fluorescent display tubes and LCDs due to manufacturing process or production lots.