The safety technology integrated in chamber ovens in the KTR .. LS range makes them suitable for many processes where flammable substance evaporate from the charge.
Sensitive products, such as some silicones, require constant, gentle movement of the charge during heat treatment. The ovens can be equipped with wire frame boxes designed to suit the rotary mechanism.
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions2 in mm | Heating power | Exhaust air volumetric flow rate | Maximum volume of solvent in g at temperature: |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
°C | w | d | h | in l | W | D | H | in kW1 | in Bm3/h | 50 °C | 100 °C | 150 °C | 200 °C | 250 °C | 260 °C | |
KTR 1000 LS | 260 | 1000 | 1000 | 1000 | 1000 | 1900 | 1430 | 2315 | 36 | 390 | 325 | 141 | 77 | 52 | 41 | 39 |
KTR 1500 LS | 260 | 1000 | 1000 | 1500 | 1500 | 1900 | 1430 | 2815 | 36 | 390 | 342 | 153 | 88 | 58 | 46 | 44 |
KTR 3100 LS | 260 | 1250 | 1250 | 2000 | 3100 | 2150 | 1680 | 3455 | 45 | 520 | 492 | 227 | 134 | 90 | 72 | 69 |
KTR 4500 LS | 260 | 1500 | 1500 | 2000 | 4500 | 2400 | 1930 | 3455 | 54 | 520 | 536 | 256 | 155 | 106 | 85 | 82 |
KTR 6125 LS | 260 | 1750 | 1750 | 2000 | 6125 | 2650 | 2200 | 3600 | 63 | 750 | 757 | 359 | 216 | 147 | 118 | 114 |
KTR 8000 LS | 260 | 2000 | 2000 | 2000 | 8000 | 2900 | 2450 | 3600 | 81 | 950 | 963 | 457 | 275 | 187 | 151 | 145 |