ASTM F88 Peeling Test - RC-601 Tensile Tester

ASTM F88 Peeling Test - RC-601 Tensile Tester

Kategori: Tensile & Tension Torque/Force Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di carlssoon-tech.com

Penerangan

Servo Universal Tensile Test Machine
ASTM F88 - Peeling Test Equipment

Brand: Rankconn Instruments
Model: RC-601 - ASTM F88




Working Principle:


Features:

Technical Parameter:

Items Tensile Strength Testing Machine
Model RC-601
Capacity 2, 5, 10, 20, 50, 100, 200,300Kg
Unit G, KG, N, LB can be exchanged
Accurate Grade 0.5grade
Display Device PC
Resolution 1/250,000
Effective Accuracy ±0.2% (0.5grade)
Max. Stroke 600mm
Speed Range 0.01-500mm/min (adjustable )
Motor Servo Motor + High Precise Ball Screw
Elongation Accuracy 0.001mm
Power AC220V, 50/60Hz (customize)
Standard Accessories Tensile clamp, Tool kit, Computer system, English software CD,
User manual





























ASTM F88  -  Seal Strength Test of Flexible Barrier Materials
 
Scope:
The ASTM F88 method covers the measurement of the strength of seals in flexible barrier materials. It is conducted on seals between a flexible material and a rigid material. Seals tested may be from any source, laboratory or commercial. ASTM F88 measures the force required to separate a test strip of material containing the seal.



Test Procedure:
 
ASTM F88 is conducted on a universal testing machine (also called a tensile testing machine) at a rate between 200 and 300 mm/min (8 to 12 in/min). The standard calls for the calculation of two measurements.
 
The maximum seal force and average force to open the seal are calculated in ASTM F88 and are reported. A portion of the force is measured while testing materials using a bending component.
 
A number of fixtures and techniques have been devised to hold samples at various angles to the pull direction to control this bending force. Because the effect of each of these on test results is varied, consistent use of one technique (unsupported, supported 90° by hand, or supported 180°) is recommended throughout the process.
 
Sample size:
ASTM F88 covers the measurement of the strength of seals in flexible barrier materials. It is conducted on seals between a flexible material and a rigid material.
 
Data:
The values in ASTM F88 are standardly stated in either SI units or inch-pound. These values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.