Sonel MPI-540-PV Solar Multi-Function Meter of Electrical and PV System Parameters with Flexible Coils and Solar Radiation Measurement Set
INDEX CAT. WMGBMPI540PVIRM1
EAN 5907624007208
Ingress protection: IP 51
Measurement category: CAT II 1000 V DC, CAT III 500 V, CAT IV 300 V
Data transmission: Bluetooth, USB, Wi-Fi
1. Multi-function meter of electrical and PV system parameters Sonel MPI-540-PV
The multifunctional meter of electrical installation parameters Sonel MPI-540-PV is an advanced tool created in particular for measuring parameters of photovoltaic installations. With the use of one device, it is possible to carry out a whole range of tests on the DC and AC sides in accordance with the guidelines of the EN 62446 standard. In addition, the Sonel MPI-540-PV is also used to carry out all measurements to determine the safety condition of domestic as well as industrial electrical installations. The presented meter is a device with advanced capabilities, dedicated to specialists operating in the installation and electrical industry.
When measuring the parameters of a photovoltaic installation, the meter automatically recalculates the parameters to the STC (Standard Test Conditions) reference conditions. Measurements of voltages, currents and power on the AC and DC side of the inverter will verify its efficiency. After transferring the data stored in the meter's memory to the Sonel Reports PLUS program, it is possible to generate a report of photovoltaic installation parameters.
In order to automate measurements, the Sonel MPI-540-PV meter has been additionally enriched with the function of testing residual current devices in Auto mode. The instrument also has measurement sequences pre-programmed by the manufacturer (so-called autotests), which can be extended with own sequences if necessary. The capabilities and functionality of the meter will be additionally enhanced by a suitably selected additional accessory, e.g. the AutoISO-1000C adapter, which enables the automatic measurement of insulation resistance of 3-, 4- and 5-core cables.
2. Solar radiation and temperature meter Sonel IRM-1
IRM-1, small, but indispensable for testing PV systems. By measuring solar radiation values, as well as panel and ambient temperatures, it provides the necessary data to convert the results into STC conditions. A built-in recorder with a memory of 5000 records enables the instrument to be used as a tool in the PV plant design process, as well as to diagnose panel shading problems.
Technical data
Measurement functions
Measurement range
Display range
Resolution
Accuracy
Fault loop impedance
Fault loop ZL-PE, ZL-N, ZL-L
0.13 Ω…1999.9 Ω acc. to IEC 61557
0.00 Ω…1999 Ω
from 0.001 Ω
±(5% m.v. + 30 digits)
Fault loop ZL-PE in RCD mode
from 0.50 Ω…1999 Ω acc. to IEC 61557
0.00 Ω…1999 Ω
from 0.01 Ω
from ±(6% m.v. + 5 digits)
Measurements of RCD parameters
RCD tripping test and measurement of tripping time tA measuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn
general and short-time delay RCD
0 ms…300 ms
0 ms…300 ms
1 ms
from ±(2% m.v. + 2 digits)
selective RCD
0 ms…500 ms
0 ms…500 ms
1 ms
from ±(2% m.v. + 2 digits)
Measurement of RCD tripping current IA measuring current 0 0.2 IΔn…2.0 IΔn
for sinusoidal residual current (AC type)
3.3 mA…1000 mA
3.3 mA…1000 mA
from 0.1 mA
±5% IΔn
for unidirectional residual current and unidirectional with the 6 mA DC bias (type A)
3.5 mA…700 mA
3.5 mA…700 mA
from 0.1 mA
±10% IΔn
for direct residual current (type B))
2.0 mA…1000 mA
2.0 mA…1000 mA
from 0.1 mA
±10% IΔn
Earth resistance
3- and 4-pole method
from 0.50 Ω…1.99 kΩ acc. to IEC 61557-5
0.00 Ω…1,99 kΩ
from 0.01 Ω
from ±(2% m.v. + 3 digits)
3-pole + clamp method
0.00 Ω…1.99 kΩ
0.00 Ω…1.99 kΩ
from 0.01 Ω
from ±(2% m.v. + 4 digits)
2-clamp method
0.00 Ω…99.9 kΩ
0.00 Ω…99.9 kΩ
from 0.01 Ω
from ±(10% m.v. + 4 digits)
Resistance-to-earth
0.0 Ω m…99.9 kΩm
0.0 Ωm…99.9 kΩm
from 0.1 Ωm
Depending on accuracy of RE measurement
Insulation resistance
Measuring voltage 50 V
50 kΩ…250 MΩ acc. to IEC 61557-2
0 kΩ…250 MΩ
from 1 kΩ
from ±(3% m.v. + 8 digits)
Measuring voltage 100 V
100 kΩ…500 MΩ acc. to IEC 61557-2
0 kΩ…500 MΩ
from 1 kΩ
from ±(3% m.v. + 8 digits)
Measuring voltage 250 V
250 kΩ…999 MΩ acc. to IEC 61557-2
0 kΩ…999 MΩ
from 1 kΩ
from ±(3% m.v. + 8 digits)
Measuring voltage 500 V
500 kΩ…2.00 GΩ acc. to IEC 61557-2
0 kΩ…2.00 GΩ
from 1 kΩ
from ±(3% m.v. + 8 digits)
Measuring voltage 1000 V
1000 kΩ…4.99 GΩ acc. to IEC 61557-2
0 kΩ…9.99 GΩ
from 1 kΩ
from ±(3% m.v. + 8 digits)
Resistance of protective conductors and equipotential bondings
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current
0.12 Ω…400 Ω acc. to IEC 61557-4
0.00 Ω…400 Ω
from 0.01 Ω
±(2% m.v. + 3 digits)
Measurement of resistance with low current
0.0 Ω…1999 Ω
0.0 Ω…1999 Ω
from 0.1 Ω
±(3% m.v. + 3 digits)
Light intensity
Measurement in luxes (lx)
0 lx…399.9 klx
0 lx…399.9 klx
from 0.001 lx
from ±(2% m.v. + 5 digits)
Measurement in feet-candles (fc)
0 fc…39.99 kfc
0 fc…39.99 kfc
from 0.001 fc
from ±(2% m.v. + 5 digits)
Phase sequence indication
in the same direction (correct), opposite direction (incorrect), UL-L voltage: 95 V…500 V (45 Hz…65 Hz)