Model KV-XLE02*1 Type Ethernet unit Connection interface RJ-45 8-position modular connector × 2 ports Transmission specification Transmission rate 10BASE-T: 10 Mbps, 100BASE-TX: 100 Mbps,1000BASE-T :1,000 Mbps*2 Transmission media 10BASE-T: Category 3 or higher UTP or STP (STP is recommended) Maximum cable length 100 m*4 Maximum number of connectable hubs 10BASE-T: 4, 100BASE-TX: 2, 1000BASE-T: 1*5 Connectable CPU units KV-8000/KV-7500/KV-7300 Refreshes Automatic refresh, direct refresh, inter-unit synchronisation refresh Ethernet functions KV socket communication, PLC link, PROTOCOL STUDIO, Industrial networks EtherNet/IP™, PROFINET, EtherCAT*8, CC-Link IE Field*9*10 Ethernet function execution methods Ladder program, unit program (flow) Unit program capacity 3 MB (max. number of blocks: approx. 20,000) Flow Maximum number of flows 256 Number of simultaneous activities Unlimited Internal data memory 524,288 words PROTOCOL STUDIO Transmission method Cyclic communication: Tx + Rx, Tx only, Rx only Maximum number of connected devices 16 Maximum number of communication commands 160 / 320*11 Maximum number of total frames Rx: 160 / 320*11 × 16 Tx: 160 / 320*11 × 1 Maximum number of compared and receive frames 16 per command Maximum number of block elements 96 per frame Transmission data length Standard: 1 to 2,048 bytes per frame Received data length PLC link Communication patterns Write, read, transfer Number of link settings 512 settings max.*12 Link data size 1,440 words max. per setting (bit: 720 words, word: 720 words) Data unit 1 word Number of connected models 16 models max.*12 Number of connected units 64 max.*12 Trigger types Cyclic / event (64 settings max. for event*12) Update interval 1 to 65,535 ms Internal current consumption 200 mA or less Weight Approx. 190 g *1 For KV-8000/KV-7000 Series
100BASE-TX: Category 5 or higher UTP or STP(STP is recommended)
1000BASE-T: Category 5e or higher UTP or STP(double-shielded STP is recommended)*3
FTP server / client, e-mail sending / receiving, KV sensor network,
Modbus / TCP server*6, MC protocol / SLMP*7, etc.
Event communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx
Extended: 1 to 16,384 bytes per frame
737,280 words max. (total)(1,440 words × 512 settings)
*2 10 Mbps / 100 Mbps / 1,000 Mbps MDI / MDI-X automatic switching function supported
*3 STP = Shielded twisted pair cable; UTP = Unshielded twisted pair cable
*4 The maximum cable length refers to the distance between the KV-XLE02 and the Ethernet switch.
*5 The maximum number is not limited when an Ethernet switch is used.
*6 Modbus is a trademark or registered trademark of Schneider Electric.
*7 SLMP is a registered trademark or trademark of Mitsubishi Electric Corporation.
*8 EtherCAT is fixed at 100 Mbps. Not usable at different transmission rates.
*9 CC-Link IE Field is fixed at 1,000 Mbps. Not usable at different transmission rates.
*10 Trademarks of each industrial network:
- EtherNet/IP™ is a registered trademark or trademark of ODVA.
- PROFINET is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V.
- CC-Link IE Field is a registered trademark or trademark of Mitsubishi Electric Corporation.
*11 The max. is 160 when “Standard” is set for the number of communication commands on the Unit Editor and 320 when “Extended” is set.
*12 Total for one KV-XLE02 unit.