KEYENCE SAFETY LASER SCANNER SZ series Malaysia Thailand Singapore Indonesia Philippines Vietnam Europe USA

KEYENCE SAFETY LASER SCANNER SZ series Malaysia Thailand Singapore Indonesia Philippines Vietnam Europe USA

Kategori: Safety Laser Scanner Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di optimuscontrol.com

Penerangan

LOOKING FOR THIS PRODUCT?

CONTACT US TODAY!! 
 
[email protected]

SZ-01S

SZ-04M

SZ-16V

SZ-16D

 
ตัวแทนจำหน่าย SAFETY LASER SCANNER THAILAND
 
จำหน่าย KEYENCE SAFETY LASER SCANNER
 

 
 
ประเทศไทย THAILAND 
[email protected]


Model

SZ-01S

SZ-04M

SZ-16V

SZ-16D

Type

Simple function type

Multi-function type

Multi-zone sets (banks) type

Measurement data output type

Detection
capability

Minimum detectable object size

Diameter 30 mm 1.18'/40 mm 1.58', 50 mm 1.97', 70 mm 2.76', 150 mm 5.91' (depends on the setting)
Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max.

Detectable angle

270° (-45° to 225°)

Response time
(ON to OFF)

General scan cycle (Scan cycle A)

60 ms (2 scans) to 480 ms (16 scans)

Specific scan cycle (Scan cycle B)

66 ms (2 scans) to 528 ms (16 scans)

Response time
(OFF to ON)

General scan cycle (Scan cycle A)

Response time of ON to OFF +125 ms

Specific scan cycle (Scan cycle B)

Max.
protection
zone

Minimum detectable object size: 70 mm 2.76'/150 mm 5.91'

4.2 m 13.78' (-5° to 185°), 2.8 m 9.19' (-45° to -5°, 185° to 225°)

Minimum detectable object size: 50 mm 1.97'

3.0 m 9.84' (-5° to 185°), 2.0 m 6.56' (-45° to -5°, 185° to 225°)

Minimum detectable object size: 40 mm 1.58'

2.4 m 7.87' (-5° to 185°), 1.6 m 5.25' (-45° to -5°, 185° to 225°)

Minimum detectable object size: 30 mm 1.18'

1.8 m 5.91' (-5° to 185°), 1.2 m 3.94' (-45° to -5°, 185° to 225°)

Max.
warning zone
(non safety
related)

Minimum detectable object size: 70 mm 2.76'/150 mm 5.91'

10.0 m 32.18' (-5° to 185°), 7.0 m 22.97' (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 50 mm 1.97'

7.5 m 24.61' (-5° to 185°), 5.0 m 16.4' (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 40 mm 1.58'

6.0 m 19.69' (-5° to 185°), 4.0 m 13.12' (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 30 mm 1.18'

4.5 m 14.76' (-5° to 185°), 3.0 m 9.84' (-45° to -5°, 185° to 225°)*1

Additional safety distance

100 mm 3.94'*2

Light source

Type, wavelength

Infrared laser diode, 905 nm

Laser class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10 *3)

OSSD output

Output

PNP or NPN (Selectable according to the connector cable)
2 outputs

PNP or NPN (Selectable according to the connector cable)
4 outputs

PNP or NPN (Selectable according to the connector cable)
2 outputs

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

OFF-state voltage

Max. 2.0 V (with a cable length of 5 m 16.4')

Leakage current

Max. 1 mA*5

Max. capacitive load

2.2 µF (with a load resistance of 100Ω)

Load wiring resistance

Max. 2.5Ω*6

Input
(safety-related)

Input resistance

4.4 kΩ (for Input 1)
2.2 kΩ (for Input 2)

4.4 kΩ (for Input 1, 3, 4, and 5)
2.2 kΩ (for Input 2 and 6)

4.4 kΩ (for Input 1 and 3 to 10)
2.2 kΩ (for Input 2)

Non
safety-related
output
(AUX output)

Output

PNP/NPN totem pole output
2 outputs

PNP/NPN totem pole output
6 outputs

PNP/NPN totem pole output
4 outputs

Non
safety-related
output
(AUX output)

Max. load current

50 mA

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

Muting lamp
output

(AUX6 output can be assigned for the
muting lamp output)

-

Can be connected to the
incandescent lamp
(24 V DC, 1 to 5.5 W) and LED
lamp (load current 10 to 230 mA)

-

 

Cable length

30 m 98.43' or less *7

Approved
standards

EMC

EMS

IEC61496-1, EN61496-1, UL 61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL 61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR)
IEC61508, EN61508, IEC62061, EN62061 (SIL2), EN ISO13849-1:2015 (PL d, Category 3) UL508, UL1998

Rating

Power voltage

When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less
When using a battery: 24 VDC +20 %/-30 %

Power consumption

Max. 9.5 W (without load)
Max. 39 W (with load)

Max. 9.5 W (without load)
Max. 50 W (with load)

Max. 10.5 W (without load)
Max. 43 W (with load)

Environmental resistance

Enclosure rating

IP65 (IEC60529)*8

Ambient light

Incandescent lamp: 1,500 lux or less*9

Operating ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage relative humidity

35 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03', 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum die casting, SPHC (Bottom)

Window

Polycarbonate

Weight

Approx. 1.6 kg

*1 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*2 If there is a high reflective background within 1.5 m 4.921' from the boundary of the protection zone, 200 mm 7.87' must be added as supplementary necessary distance to the protection zone in case of calculation of the minimum safety distance.
*3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*4 For the load current calculation of the OSSD output and the AUX output, make sure it is 1.5 A or less when using converter power supply (or 1.0 A or less when the cable length is 25 m 82.02' or more),
and 1.0 A or less when using a battery (or 0.5 A or less when the cable length is 5 m 16.40' or more)
*5 This also takes into account the situations when power is either off or disconnected.
*6 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operation. However, it must be 1.0 Ω or less if the load current is 300 mA or more.
*7 It must be 10 m 32.81' or less if the power is supplied by battery.
*8 When the setting cover is open, or the connector cable is not connected, the IP65 certification cannot be met. In addition, the SZ-16D doesn't fulfill the requirements of IP65 degree of protection with the connector cable for the RS-422A communication unattached..
*9 The SZ should not be installed so as to have light interference within ±5° to the detection plane.




 

Lebih maklumat tentang Optimus Control Industry PLT
Optimus Control Industry PLT
Optimus Control Industry PLT Automation & Control Components Supplier Malaysia, Encoder Distributor Kuala Lumpur (KL), Industrial Sensor Supply Selangor | Optimus Control Industry PLT