Model |
IX-1000 |
|||
Main unit / expansion unit |
Main unit |
|||
Display |
Min. display unit |
10 µm*1 |
||
Display range |
±999.99 to ±999 mm (with 4 selectable steps)*1 |
|||
Tools |
Scan mode |
Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment |
||
Line mode |
Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction |
|||
Other functions |
Common |
ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, |
||
Scan mode |
Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination, |
|||
Line mode |
Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.) |
|||
Input |
Input |
Non-voltage input/voltage input is switchable |
||
Number of inputs |
8 (IN1 to IN8) |
|||
Function |
IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions |
|||
Output |
Output |
Open collector output; NPN/PNP switchable, N.O./N.C. switchable |
||
Number of inputs |
10 (OUT1 to OUT10) |
|||
Function |
Enable by assigning the optional functions |
|||
Analog voltage output |
±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 !&*3 |
|||
Analog current output |
4 to 20 mA, max. load resistance: 350 !&*3 |
|||
Number of programs |
32 |
|||
Statistical information |
Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) |
|||
Detection record |
Number of storage |
Scan mode |
80 images (FTP/SFTP Client function: Enable) |
|
Line mode |
400 images (FTP/SFTP Client function: Enable) |
|||
Detection history |
Save conditions |
NG only/All is selectable*5 |
||
FTP/SFTP data transfer (FTP/SFTP client function) |
Transfer Destination |
FTP/SFTP server |
||
Transfer format |
bmp/jpeg/txt is selectable |
|||
Transfer Condition |
4 conditions |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*6 |
||
Connector |
RJ45 8-pin connector*6 |
|||
Interface compatibility |
CC-Link / DeviceNet® / EtherNet/IP™ / EtherCAT$ / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7 |
|||
Number of connectible units |
Main units: 1, Expansion units: 1, Communication units (DL) : 1 |
|||
Ratings |
Power voltage |
24 VDC ±10 % (including ripple) |
||
Current consumption |
Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8 |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/ |
|||
Weight |
Approx. 210 g |
|||
*1 For displaying on an IX Series control panel or PC software. |