Product overview: Fluke 705 Loop Calibrator
Fluke 705 loop calibrator provides a cost-effective, integrated solution for calibrating milliamp loops
The Fluke 705 is a cost-effective, integrated solution for calibration, repair and maintenance of milliamp loops. It features a large display and simple, pushbutton interface for ease of use. Plus, it offers the other capabilities you need most to calibrate mA loops including:
- mA sourcing, simulation and measurement
- 0.02% accuracy and 0.001 mA resolution
- Simultaneous mA and % of span display
- Selectable step or ramp outputs
- 24 V Loop supply with mA measure
- 0-28 VDC measurement to check Loop Voltage
- Easy battery exchange without opening the case
- Includes “span check” for fast confirmation of zero and span.
- Provides selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
- Includes a 24 volt internal loop supply, so you can power and read a transmitter at the same time without a DMM.
- Runs on a single 9 V battery that is easily changed without breaking the calibration seal
- Offers 0 - 20 mA or 4 - 20 mA default start up modes
- Comes with a protective yellow holster with test lead storage and a three year warranty
And you get all of that in a compact case with a separate protective holster and a three year warranty.
What's in the box:
- Fluke 705 Loop Calibrator
- C10 protective yellow holster with Flex-Stand™
- (1 set) AC70A Alligator Clips
- Instruction sheet
- (1 pair) TL75 safety-designed test leads
- NIST- traceable calibration report and data
- Quick Reference Guide
- 3-year warranty
Specifications: Fluke 705 Loop Calibrator
Specifications |
Current measurement |
Range |
0 to 24 mA |
Resolution |
0.001 mA |
Accuracy |
0.02% Rdg + 2 LSD |
Current sourcing |
Range |
0 to 20 mA or 4 to 20 mA |
Accuracy |
0.025% Rdg + 2 LSD |
Drive capability |
1000 Ω @ 24 mA |
Current simulation |
Range |
0 to 20 mA or 4 to 20 mA |
Accuracy |
0.025% Rdg + 2 LSD |
Ext. loop voltage requirement |
12-30 V |
Loop power |
While measuring mA, 24 V |
Voltage measurement |
Range |
0 to 28 V DC |
Resolution |
1 mV |
Accuracy |
0.025% Rdg + 2 LSD |
Environmental Specifications |
Operating temperature |
-10°C to 55°C |
Storage temperature |
-40°C to 60°C |
Humidity (without condensation) |
0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C) |
Temperature coefficient |
-10°C to 18°C, 28°C to 55°C, ±.005% of range per°C |
Safety Specifications |
Safety |
CSA C22.2 No. 1010.1:1992 |
EMC |
EN50082-1:1992 and EN55022:1994 Class B |
Maximum voltage |
30 V |
Mechanical and General Specifications |
Size |
152 x 70 x 41 mm |
Weight |
340 g |
Batteries |
One 9 V battery |
Warranty |
Three years |
Shock and vibration |
per MIL-T-28800 for a Class 2 Instrument |
Display current and % of span |
Yes |
Auto step, auto ramp |
Yes |
Span check |
Yes |
Models: Fluke 705 Loop Calibrator
Fluke 705
Fluke 705 Loop Calibrator
Includes:
- AC70A Alligator Clips
- C10 protective yellow holster with Flex-Stand™
- Instruction sheet
- TL75 safety-designed test lead set
- NIST- traceable calibration report and data