Type | Diffuse reflective |
Long sensing range spot reflective | |
Class 2 | |
IEC / JIS / GB standards conforming type | LS-H21 |
CE marking directive compliance | EMC Directive, RoHS Directive |
Applicable amplifiers | LS-401(P), LS-401(P)-C2, LS-403 |
U-LG mode | 30 to 1,000 mm |
1.181 to 39.370 in | |
STD mode | 30 to 500 mm |
1.181 to 19.685 in | |
FAST mode | 30 to 300 mm |
H-SP mode | 1.181 to 11.811 in |
Operation indicator | Orange LED (lights up when the amplifier output is ON) |
Laser emission indicator | Green LED (lights up during laser emission) |
Spot-shape adjuster | Multi-turn adjuster |
Ambient temperature | -10 to +55 ℃ +14 to +131 ! (No dew condensation or icing allowed) |
Storage: -20 to +70 ℃ -4 to +158 ! | |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: PBT (Mounting part: PEI), Lens cover: Acrylic |
Cable | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note 5) |
Weight | Net weight: 30 g approx. |
Gross weight: 40 g approx. | |
Accessories | Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) |