Fluke 6200-2 Portable Appliance Testers Malaysia

Fluke 6200-2 Portable Appliance Testers Malaysia

Kategori: FLUKE Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di sjtsuccess.com.my

Penerangan

Specifications: Fluke 6200-2 Portable Appliance Testers

Specifications
Test specifications The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
Power-on test The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
Display range 90 V to 264 V
Accuracy at 50 Hz ±(2% + 3 counts)
Resolution  1 V
Input impedance       > 1 MΩ // 2.2 nF
Maximum input mains voltage 264 V
Earth bond test (R pe) Display Range 0 to 19.99 Ω
Accuracy (after bond test zeroing) ±(2.5% + 4 counts)
Resolution 0.01 Ω
Test current 200 mA AC -0% +40% into 1.99 Ω
25 A AC ±20% into 25 mΩ at 230 V
Open circuit voltage > 4 V AC, < 24 V AC
Bond test zeroing can subtract up to 1.99 Ω
Insulation test (R iso) Display range 0 to 299 MΩ
Accuracy ±(5% + 2 counts) from 0.1 to 300 MΩ
Resolution 0.01 MΩ (0 to 19.99 MΩ)
0.1 MΩ (20 to 199.9 MΩ)
1 MΩ (200 to 299 MΩ)
Test voltage 500 V DC -0% + 10% at 500 kΩ load
Test current > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
Auto discharge time < 0.5 s for 1 μF
Max. capacitive load Operational up to 1 μF
Touch current test Display range 0 to 1.99 mA AC
Accuracy ±(4% + 2 counts)
Resolution 0.01 mA
Internal resistance (via probe) 2 kΩ
Measuring method Probe*
Substitute leakage current test Display range 0 to 19.99 mA AC
Accuracy ±(2.5% + 3 counts)
Resolution 0.01 mA
Test Voltage 100 V AC ±20%
Load/leakage test: load current Display range 0 A to 13 A
Accuracy ±(4% + 2 counts)
Resolution 0.1 A*
Load/leakage test: load power Display range 230 V Mains 0.0 VA to 3.2 kVA
Accuracy  ±(5% + 3 counts)
Resolution 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*
Load/leakage test: leakage current Display range 0 to 19.99 mA
Accuracy ±(4% + 4 counts)
Resolution 0.01 mA*
PELV test Accuracy at 50 Hz ±(2% + 3 counts)
Overload protection 300 V rms
Warning threshold 25 V rms
*The appliance under test is energized at mains potential.
 
Environmental specifications
Operating temperature 0 to 40 °C
Relative humidity Non condensing <10 °C
95% from 10 to 30 °C
75% from 30 to 40 °C
 
Safety specifications
Safety rating Complies with EN61010-1 3rd edition
CAT II, 300 V, pol 2
 
Mechanical and general specifications
Size (L x W x H) 200 x 275 x 114 mm
Weight 3.13 kg
Power supply 230 V +10% -15%, 50 Hz ±2
Power consumption (tester) 13 W typical (idle)
60 W max. during 25A Bond test
Storage Temperature -10 to 60 °C
Corrosion 70 °C @ 95% RH for 5 days max.
Operating altitude 0 up to 2000 m
Sealing IP-40 (enclosure), IP-20 (connectors)
EMC Complies with EN61326-1, portable
EMI Immunity 3 V/m