Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage |
Range ¹ |
Resolution |
Accuracy ² ³ |
45 Hz to 500 Hz |
500 Hz to 1 kHz |
6.000 V |
0.001 V |
1.0 % + 3 |
2.0 % + 3 |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. |
General Specifications |
LCD w/backlight
|
3½ digits, 6000 counts, updates 4/sec
|
Battery type
|
2 AA, NEDA 15 A, IEC LR6
|
Battery life
|
400 Hours
|
Memory
|
Record up to 65,000 readings
|
Unbound listen interval
|
5 seconds
|
RF communications
|
2.4 GHZ ISM Band
|
RF communication range
|
20 Meters
|
Operating temperature
|
-10 °C to +50 °C
|
Storage temperature
|
-40 °C to +60 °C
|
Operating humidity
|
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
|
EMC
|
EN 61326-1:2006
|
Safety compliance
|
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008
|
Pollution degree
|
2
|
Temperature coefficient
|
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
|
Safety rating
|
CAT IV 600 V, CAT III 1000 V
|
Certifications
|
CSA, FCC T68-FWCS IC:6627A-FWCS
|
Ingress Protection (IP) rating
|
IP42
|
Size (HxWxD)
|
16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
|
Weight
|
.22 kg (8 oz)
|
|
|
|
|