Fluke VT04 Visual IR Thermometer
Key Features |
Built-in digital camera |
Yes |
Thermal heat map overlay |
Yes, five blending modes |
Image optics system |
PyroBlend® Plus optic *4x sharper image than VT02 |
Field of view |
28° x 28° |
Hi-Lo temperature alarms |
Yes |
Time lapse image capture |
Yes |
Auto-monitor alarm |
Yes |
Battery type |
Li-Ion rechargeable |
Training |
No training required |
Ergonomics |
Slim pocket-sized design |
Hot and cold markers |
Yes |
General Features |
Battery life |
Eight (8) hours |
Temperature measurement range |
-10 °C to +250 °C (14 °F to 482 °F) |
Temperature measurement accuracy |
+/- 2 °C or +/- 2 % |
Temperature measurement |
Yes, centerpoint |
Storage medium (micro SD card) |
Stores up to 10,000 images per Gb (Four (4) Gb card included) |
Infrared spectral band |
6.5 μm to 14 μm |
Level and span |
Auto |
Focus mechanism |
Focus free, no training required with built-in intelligence |
Focus options-exclusive user selectable NEAR/FAR options |
NEAR < 23 cm (9 in); FAR > 23 cm (9 in) |
Dimensions |
21 cm x 7.5 cm x 5.5 (8.3 in x 3 in x 2.2 in); < 350 g. (12.5 oz.) |
File format |
.is2 format saved to SD card. User can create professional reports or export images in SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF and TIFF) |
Safety and compliance |
CFR47: 2009 Class A. Part 15 subpart B; CE: EN 61326:2006; IEC/EN 61010-1:2010 |
Warranty |
Two (2) years |
Fluke 902 True-rms HVAC Clamp Meter
Specifications |
Voltage DC |
Range |
0 – 600.0 V |
Accuracy |
1% ± 5 counts |
Voltage AC (True RMS) |
Range |
0 – 600.0 V |
Accuracy |
1% ± 5 counts (50/60 Hz) |
Current AC (True RMS) |
Range |
0 – 600.0 A |
Accuracy |
2.0% ± 5 counts (50/60 Hz) |
Current DC |
Range |
0 - 200.0 µA |
Accuracy |
1.0% ± 5 counts |
Resistance |
Range |
0 – 9999 Ω |
Accuracy |
1.5% ± 5 counts |
Continuity |
<= 30 Ω |
Temperature*
(Type K Thermocouple) |
Range |
-10 degree C to 400 degree C
(-14 degree F to 752 degree F) |
Accuracy |
+/- 1.0% + 0.8 degree C
(+/- 1.0% + 1.5 degree F) typical |
Range |
-40 degree C to -10 degree C
(-40 degree F to -14 degree F) |
Accuracy |
+/- 5.0% + 1.5 degree C
(+/- 5.0% + 3.3 degree F) typical |
Capacitance |
Range |
1-1000 µF |
Accuracy |
1.9% ± 2 counts |
* Error does not include Type K Thermocouple errors
Mechanical and General Specifications |
Weight |
1.5 lbs (.7 kg) |
Dimensions |
10.75 x 4.25 x 2.44 (27.3 cm x 10.8 cm x 6.2 cm) |
Battery type |
(2) AA Alkaline Batteries |
Fluke 116 Digital Multimeter
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating temperature |
-10 °C to + 50 °C |
Storage temperature |
-40 °C to + 60 °C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range/Resolution |
600.0 mV / 0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range/Resolution |
600.0 V / 0.1 V |
Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts ¹ True RMS |
Range/Resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts ¹ True RMS |
Range/Resolution |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range/Resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of
500 μs or longer. |
Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9 % + 1 |
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
5 % + 2 |
Diode Test |
Range/Resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/Resolution |
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
Range/Resolution |
> 1000 μF |
Accuracy |
5% + 20% |
Lo-Z Capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
Temperature²
(Type-K thermocouple) |
Range/Resolution |
-40 °C to 400 °C / 0.1 °C |
Accuracy |
1% + 10² |
Range/Resolution |
-40 °F to 752 °F / 0.2 °F |
Accuracy |
1% + 18² |
AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
DC μamps |
Range/Resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
Hz (V or A input)² |
Range/Resolution |
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
Notes:
-
All AC voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
-
Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
-
Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
-
Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.
Mechanical and General Specifications |
Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight |
550 g |
Warranty |