Auto-Ranging on Volt, Ohm, Current,
Frequency measurements.
Auto-power off.
Data Hold mode.
MAX/MIN Hold mode.
Zero/Adjustment/Relative Reading.
Specification
DC Voltage(Autorange & Manual)
Range
Resolution
Accuracy
Input Impedance
Overload protection
400mV
0.1 mV
±(0.75%rdg+2dgts)
≧1000MΩ
660Vrms
4V
0.001V
≒ 11MΩ
40V
0.01V
≒ 10MΩ
400V
0.1V
600V
1V
AC Voltage(Autorange & Manual)
Range
Resolution
Accuracy
Input impedance
Overload protection
Frequency Response
4V
0.001V
±(1.2%rdg +5dgts)
≒ 11MΩ
660Vrms
40~450Hz
40V
0.01V
≒ 10MΩ
400V
0.1V
600V
1V
±( 1.5%rdg
+ 5dgts)
AC Current(Autoange & Manual)
Range
Resolution
Accuracy
Overload protection
Frequency Response
400A
0.1A
±( 2%rdg + 10 dgts )
1100A
40~450 Hz
1000A
1 A
Frequency ( Hz )(Autorange only for current)
Range
Resolution
Accuracy
Sensitivity
Overload protection
100 Hz
0.01 Hz
±( 0.5%rdg+5dgts)
5A
1100A
1KHz
0.1 Hz
Frequency ( Hz )(Autorange only for voltage)
Range
Resolution
Accuracy
Sensitivity
Overload protection
100 Hz
0.01 Hz
±( 0.1%rdg+2dgts)
100mV
660Vrms
1KHz
0.1 Hz
10KHz
0.001KHz
100KHz
0.01 KHz
800KHz
0.1 KHz
1V
Resistance ( Ω )(Autorange & Manual)
Range
Resolution
Accuracy
Open circuit Voltage
Overload protection
400Ω
0.1Ω
±( 1%rdg+5dgts)
≦0.5 VDC
660Vrms
4KΩ
0.001KΩ
±( 1%rdg+3dgts)
40KΩ
0.01 KΩ
400KΩ
0.1 KΩ
4MΩ
0.001MΩ
40MΩ
0.01 MΩ
±( 1.5%rdg+3dgts)
Audible Continuity
Range
Continuity beeper
Open Circuit Voltage
Overload protection
≦40Ω
≦0.5V
660Vrms
Diode test
Range
Resolution
Accuracy
Overload protection
0.001V
±( 1%rdg+2dgts )
660Vrms
SPECIFICATIONS Numerical Display :3 3/4 digit liquid crystal display (LCD) maximum reading 3999. Range Selection :All ranges are selected by a single range switch. Over Range Indication:LCD will show a "4" flashing in the highest position accompanied with a continuous beeping. (except for ranges of 1000A AC , and 600VDC 600VAC ). LowBattery Indication:The is displayed when the battery voltage drops below the operating voltage. Sampling Rate : 20 times/sec ( Barograph )2 times/sec (Digital Display) Power Source :one 006p 9V or IEC 6F22or NEDA 1604 Battery. Battery Life :300hr approx. (Alkaline) Polarity :Automatic polarity "–" display for negative input. Auto power off time :Approx. 30 minutes. Operating Temperature:0℃ to 50℃ and Humidity (32℉ to 122℉) below 80%RH StorageTemperature :-10℃ to 60℃ and Humidity (14℉ to 140℉) below 70%RH Dimensions :239(L)x66(W)x34(H)mm Weight :Approx. 430g
Obsnap Instruments Sdn BhdTesting Instruments Supplier Malaysia, Measuring Equipments Supply Selangor, Simulation Systems Supplies Kuala Lumpur (KL) ~ Obsnap Instruments Sdn Bhd