The Fluke T5 Electrical Testers let you check voltage, continuity and current with one compact tool. With the T5, all you have to do is select volts, ohms, or current and the tester does the rest. OpenJaw™ current lets you check current up to 100A - without breaking the circuit. Its tough test leads stow neatly in the back of the tester, making it easy to tote the T5 in your tool pouch. Detachable SlimReach™ test probes are customized for national electrical standards. The test leads accept optional accessories such as clips and specialty probes. The optional H5 holster lets you clip the T5 onto your belt.
All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.
Specifications | |
Jaw opening | 12.9 mm (0.5 in) |
Max wire size | 1/0 THHN Cable |
Current range ac rms | 0 to 100.0 A |
Accuracy ac current (50/60 Hz) | 3 % ± 3 counts |
AC Response | Averaging |
Voltage range ac | 0 to 600 V |
Accuracy ac voltage | 1.5 % ± 2 counts |
Voltage range dc | 0 to 600 V |
Accuracy dc voltage | 1 % ± 1 count |
Resistance range | 0 to 1000 Ω |
Continuity beeper threshold | On at <25 Ω, off at >400 Ω |
Volts indicator LED threshold | Guaranteed on by 30 V ac |
Environmental Specifications | |
Operating Temperature | -10 °C to 50 °C |
Storage Temperature | -30 °C to 60 °C |
Humidity (Without Condensation) |
0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C); 0 % to 45 % (40 °C to 50 °C) |
Dust/water resistance | Yes |
Operating Altitude | 2000 meters max |
Temperature Coefficient | 0.1 x (specified accuracy)/°C (<18 °C or >28 °C) |
Safety Specifications | |
Overvoltage category | CAT III 600 V ac/dc (EN61010-1) |
Agency Approvals | UL, CSA, and VDE |
Maximum voltage | Between any terminal and earth ground |
Mechanical and General Specifications | |||||||||||
Size | 30.5 mm x 51 mm x 203 mm | ||||||||||
Weight | 300g | ||||||||||
Warranty | Two-years | ||||||||||
Battery Life | 200 hour zinc chloride, 400 hour alkaline | ||||||||||
Battery type | 2 x AA | ||||||||||
Low battery indicator | Yes | ||||||||||
Current sensor opening | 12.9 mm | ||||||||||
Calibration cycle | 1 year | ||||||||||
Test leads |
|