Dual setting type temperature controller T4LP series can control heating and cooling at a time and realize high accuracy measurement of ±0.5% based on F•S value of each input. Also, it is dual setting type product that allows optimal low temperature controlling and high accuracy controlling. The series contributes to better user convenience by adopting digital switches.
Main features
● Dual setting type
● High accuracy measuring function: ±0.5%
● Control heater and cooler at once
● Use dual setting type of temperature when executing low temperature or precision control. In dual setting control type, the single output is operated as reverse, it is used for heater control. The dual output is used to control the operation of cooler normally. The dual output is also used for an alarm.
Specification Table
Model | T4LP | |
Power supply | 110/220VAC 50/60Hz | |
Allowable voltage range | 90 to 110% of rated voltage | |
Power consumption | Max. 3VA | |
Display method | 7 Segment LED method | |
Character size(W×H) | 9.5×14.2mm | |
Display accuracy | F.S. ±0.5% rdg ±1digit | |
Setting type | Digital setting | |
Setting accuracy | F.S. ±0.5% | |
Sensor input | Thermocouples: K(CA), J(IC), R(PR) / RTD: DPt100Ω | |
Input line resistance | Thermocouples: Max. 100Ω, RTD: Allowable line resistance max. 5Ω per a wire | |
Control method | ON/OFF control | Hysteresis: F.S. 0.2 to 3% variable |
P control | Proportional band: F.S. 1 to 10%, Period: 20sec. fixed | |
RESET adjuster range | F.S. ±3% variable (revision of control deviation / only for P control) | |
Control output |
• Relay contact output: 1st out: 250VAC 3A 1c, 2nd out: 250VAC 2A 1c • SSR drive voltage output: 24VDC ±3V 20mA Max. • Current output: DC4-20mA (load 600Ω Max.) |
|
Self-diagnosis | Built-in burn out function (cut off output when sensor is disconnected) | |
Insulation resistance |
Min. 100MΩ(at 500VDC megger) Dielectric strength |
|
Dielectric strength | 2000VAC 50/60Hz for 1 minute | |
Noise strength | ±2kV the square wave noise(pulse width:1㎲) by the noise simulator | |
Vibration | Mechanical | 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour |
Malfunction | 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) In each of X, Y, Z directions for 10 min. | |
Shock | Mechanical | 300m/s²(Approx. 30G) in each of X, Y, Z directions for 3 times |
Malfunction | 100m/s²(Approx. 10G) in each of X, Y, Z directions for 3 times | |
Relay life cycle | Mechanical | Min. 10,000,000 operations |
Electrical | Min. 100,000 operations(250VAC 3Aat resistive load) | |
Environment | Ambient temperature | -10 to 50℃, storage: -25 to 65℃ |
Ambient humidity | 35 to 85%RH, storage: 35 to 85%RH | |
Unit weight | Approx. 487g |