Force in 3 dimensions(X, Y, Z) can be measured at the same time
±5V output at the rated capacity for each direction: Fx, Fy, Fz (three axis).
As output signals for each direction is adjusted before shipping out, you can get calibrated(scaled) output by just connecting sensor and DC24V power supply to FS300.
Model | Sensor:UPP-100NX3, Amplifier:FS300 |
---|---|
Rated capacity | Fx, Fy : ±100N、Fz : 100N |
Power supply voltage | DC24V±15% |
Consumption current | 150mA or less |
Load signal output | Fx、Fy、Fz:±5V |
Load resistance | 2kΩ or more |
Response | 2kHz |
I/O signal |
Input: Auto zero command Output: Auto zero response |
Safe overload | 500%FS |
Non-linearity | 0.5%FS |
Hysteresis | 0.5%FS |
Repeatability | 0.5%FS |
Compensated temperature range | 0 to +40℃ |
Safe temperature range | -10 to +50℃ |
Temperature effect on zero | 0.5%FS/℃ |
Temperature effect on span | 0.05%FS/℃ |
Sensor material | Aluminum alloy |
Weight |
Sensor:Approx. 70g、 Amplifier:Approx. 180g (Excluding the cable) |
Cable |
8 conductor flexible cable 1m (Connector is included for FS300 connection) |
* Above specifications are achieved when the sensor(UPP-100NX3) is connected with the dedicated amplifier(FS300).
* Accuracy is not guaranteed in the range of Fz 0 to -5V.
Product catalogue(PDF)
|
UPP-100NX3 catalogue(553 KB) |
---|