Description
ZBL Series
Product snapshot:
Model |
1-10KVA (1Ph in / 1Ph out) |
Model |
10-20KVA (3Ph in / 1Ph out) |
Nominal Voltage |
220 / 230 / 240 / VAC (1-10KVA) |
Nominal Voltage |
380 / 400 / 415 VAC (10-20KVA) |
Nominal Frequency |
50 / 60Hz |
Output Power Factor |
1.0 |
Stable, Reliable and Comprehensive Protection
ZBL series 1-20KVA adopts double conversion true online architecture, which is designed to cater for various power related issues. The state-of-art solution can solve power loss and impurities such as over- and under-voltage, voltage sags or damped oscillation, high-voltage pulse, voltage fluctuation, voltage surge, harmonic and frequency distortion problems. It delivers a clean, safe and reliable power supply to your electrical or electronic loads.
Key Features
-
Its cutting-edge digital technology of DSP(Digital Signal Processor) can greatly improve the products performance and system reliability, and deliver a compact integration with higher power density;
-
Output power factor up to 1.0 - applicable to the trend of future load evolution, and deliver higher payload capacity;
-
Higher payload and overload capability, better load compatibility, and suitable for various load type;
-
Total power factor up to 90% can minimize the power loss of UPS and utilization cost for user;
-
High Scalability: fully meet the customer's demands;
-
Powerful Interference immunity capability in compliance with EMC requirements of IEC61000-4, deliver your device a clean electric environment.
High Reliability
-
Its cutting-edge digital control technology of DSP(Digital Signal Processor) can deliver higher quality, performance and reliability;
-
Higher payload and overload capability, better load compatibility, and suitable for various load type;
-
Powerful Interference immunity capability in compliance with EMC requirements of IEC61000-4, deliver your device a clean electric environment.
Flexible Configuration on Demand
-
High Scalability: fully meet the customer's demands;
-
Online Intervention: safe and online intervention without any power supply interruption to load;
-
Parallel Kit: realize the parallel extension and redundancy function, offer more flexibility and safety for user's power supply planning;
-
Isolating Transformer: offer isolation protection for the user.
Tailored for Grid Environment
-
Output power factor up to 1.0 - applicable to the trend of future load evolution, and deliver higher payload capacity;
-
Total efficiency of more than 90% can minimize the power loss of UPS and utilization cost for user;
-
Active power factor correction(PFC) technology allows the input power factor approaching to 1, dramatically reducing the immunity on utility grid;
-
Wider range of input voltage tailored for all severe environments;
-
Excellent input frequency range makes UPS suitable to different power supply devices, i.e generator set.
Intelligent battery management
-
With its advanced intelligent charge control mode, UPS can automatically select the optimal charge mode as per the battery type and conditions, thus further maximizing the lifespan of battery bank. In addition, the system can periodically conduct the charge & discharge management for the battery bank. User also can select the battery voltage (192V or 240V) on demands.
-
The user can query and set the proper UPS control parameters for intelligent UPS mangement; automatically identify and adapat to 50/60Hz power supply system, fulfilling the requirements in various power supply systems;
-
Perfect failure protection and alarm function: provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery over-charge or under-voltage, overload, and short circuit.
Compact Design, Lower Noise
-
With leading control technology and craftsmanship, this UPS can greatly increase the power density and reduce the footprint, therefore save more expensive space in your office environment. Additionally, its lower noise during operation can allow you a more comfort working environment.
Rich Communication and Monitoring Features
-
Provide RS232, USB interface and communication cable for local or remote power supply management;
-
Provide intelligent slot available to Web Power (SNMP), CMC, or AS400 card (dry contact) for remote management and monitoring function.
User-friendly interface
-
LCD display accurate UPS working environment and working status to the user, through the LCD display panel can be set output voltage and frequency, convenient for user to operate the UPS.
Intelligent Power monitoring and Management Software WinPower2003
-
Support Microsoft Windows95/Me/NT/2000/XP/Unux operating system. Suit for TCP/IP local area network;
-
Support TCP/IP network monitoring; Provide a hierarchical directory structure management network; Unusual event can be notified to user through broadcast, e-mail, messenger call or mobil messager; Automatically detective the UPS model and the communication post; Provide password protection;
-
Support timing boot up / shut off UPS function;
-
Support timing UPS self-test function;
-
Support graphically displayed UPS status function in real time;
-
Support network to deactivate the function of multiple servers and workstations;
-
Support Smart Event function, so that the user can defined according to their needs;
-
Accept the abnormal power;
-
Support to shut off most of the applications and the preservation of related document;
-
Support for English and multi-language platform;
-
Support the online help function; with date records(including mains, UPS, load, battery), and event function, to convenient the system administrator for the routine maintenance.
More detail about MicroMate Industries Sdn Bhd