IR-22 non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) and RS-485 communication signal output.
It can measure from -60 ℃ to maximum 380℃ and RS-485 communication enables to store data in computer.
IR-22 has a high precision by adopting optical lens which can enable to measure target exactly at a long distance through its 10:1 D:S (Distance to Spot).
[ Applications ] |
Plastics, Fluids, Rubber, Coated components, Asphalt, Wood, Paper, Ceramics, Textiles, Glass, Food etc. |
|
[ Specification ] |
|
|
Measurement Range |
-60℃ ~380℃ |
Device |
Thermopile |
Accuracy |
±1% / full scale |
Repeatability |
±1% of reading |
Distance : Spot |
10:1 |
Optical spectrum wave |
8~14㎛ |
Responsive Time |
0.1 sec or below |
Emissivity |
0.95 fixed
((Changeable when using PC software program) |
Analog Output |
4~20mA |
Communication |
RS-485 |
Power |
DC 12~24V(Max 50mA) |
Ambient temperature |
-20~70℃ |
Temperature Resolution |
0.1℃ |
Operating Relative Humidity |
5~90% |
Storage temperature |
-30~85℃ |
Dimension |
Ø16 ×70.5(L) |
Housing material |
SUS |
Weight |
75g |
Cable lenght |
1m (standard), other(option) |
|
|
|
[ Code Number IR-Compact-□□□ ] |
|
|
Model |
Description |
IR-22 |
|
Code A |
Temperature Range |
1 |
-60~380℃ |
2 |
0~200℃ |
Z |
Other |
Code B |
Output |
M |
DC 0~20mA |
N |
DC 4~20mA |
Z |
Other |
Code C |
Cable Length |
1 |
1m Cable |
Z |
Other (option) |
|
|
|
[Optical Field of View ] |
|
|
|
|