KYORITSU MODEL 2432

KYORITSU MODEL 2432

Category: Clamp Meter Available
For more information, visit our official website at mobicon.my

Description

• High Sensitive Model

• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA.
 
AC A (50/60Hz) 4/40mA/100A
±1%rdg±5dgt (4/40mA)
±1%rdg±5dgt (0 - 80A)
±5%rdg (80.1 - 100A)
AC A (WIDE) 4/40mA/100A
±1%rdg±5dgt [50/60Hz], 
±2.5%rdg±10dgt [20Hz - 1kHz] (4/40mA)
±1%rdg±5dgt [50/60Hz], 
±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 80A)
±5%rdg [50/60Hz], 
±10%rdg [40Hz - 1kHz] (80.1 - 100A)
Maximum circuit voltage 600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size Ø40mm max.
Frequency response 20Hz - 1kHz (40Hz - 1kHz:100A)
Effect of External Stray Magnetic Field 2mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response Time Approx. 2 seconds
Power source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 290g approx.
Included Accessories 9097 (Carrying Case) 
R03 (1.5V) × 2
Instruction Manual

Product Catalogue