EXTECH 380193: Passive Component LCR Meter

EXTECH 380193: Passive Component LCR Meter

Category: LCR METER Available
Purchasable on official site
For more information, visit our official website at accutac.com.my

Description

EXTECH 380193: Passive Component LCR Meter

Measures Inductance, Capacitance, and Resistance with secondary parameter
(Q,D,R)


Extech 380193 
 
Specifications Range Basic Accuracy
Inductance 2000.0µH, 20.000mH, 200.00mH, 2000.0mH 20.000H, 200.00H, 2000.0H, 10000H ±(0.7%rdg)
Capacitance 2000.0pF, 20.000nF, 200.00nF, 2000.0nF, 20.000µF, 200.00µF, 2000.0µF ±(0.7%rdg)
Resistance 20.000Ω, 200.00Ω, 2.0000kΩ, 20.000kΩ, 200.00kΩ, 2.0000MΩ, 20.000MΩ ±(0.5%rdg)
DF (with C) 0 to 0.9999 ±(0.7%rdg)
Q 0 to 9999 ±(1.2%rdg)
Test Freq. 120Hz and 1kHz
Dimensions/Weight 7.56x3.58x2.1'' (19.2x9.1x5.25cm) / 12.87oz (365g)