6-Monoacetylmorphine (6-MAM) Rapid Test - Urine

6-Monoacetylmorphine (6-MAM) Rapid Test - Urine

Category: JusChek Available
For more information, visit our official website at setiascientific.com

Description

【SUMMARY】

6-Monoacetylmorphine (6-MAM) or 6-acetylmorphine (6-AM) is one of three active metabolites of heroin (diacetylmorphine), the others being morphine and the much less active 3-monoacetylmorphine (3-MAM). 6-MAM is rapidly created from heroin in the body, and thenis either metabolized into morphine or excreted in the urine. 6-MAM remains in the urine for no more than 24 hours. So a urine specimen must be collected soon after the last heroin use, but the presence of 6-MAM guarantees that heroin was in fact used as recently as within the last day. 6-MAM is naturally found in the brain, but in such small quantities that detection of this compound in urine virtually guarantees that heroin has recently been consumed.

【DIRECTIONS FOR CASSETTE USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Results may be stable up to 1 hour after test initiation.

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

 

 

 

 

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DMA-102

6-Monoacetylmorphine (6-MAM) Rapid Test Cassette

Urine

Cassette

40 T

10 ng/mL*

CE

DMA-114

6-Monoacetylmorphine (6-MAM)Rapid Test Panel

Urine

Panel

40 T

CE

DMA-101

6-Monoacetylmorphine(6-MAM) Rapid Test Dipstick

Urine

Dipstick

50 T

CE


More detail about Setia Scientific Solution
Setia Scientific Solution
Setia Scientific Solution Medical Supplies Kuala Lumpur (KL), Laboratory Instruments Supply Selangor, Diagnostic Test Kits Supplier Malaysia ~ Setia Scientific Solution
Contact Us flagMalaysia