RH Room Combo Wall Sensor NSA-RH-ROOM Part Numbers NSA-HH:RH2-CP-R2-C NSA-HH:RH3-CP-R2-C

RH Room Combo Wall Sensor NSA-RH-ROOM Part Numbers NSA-HH:RH2-CP-R2-C NSA-HH:RH3-CP-R2-C

Category: Carrier Available
For more information, visit our official website at unitedfaith.com.my

Description

Part Numbers

NSA-HH/RH2-CP-R2-C
NSA-HH/RH3-CP-R2-C

The Carrier Relative Humidity with Thermistor Room Series utilizes a thermoset polymer capacitive sensing element with a factory fitted hydrophobic filter to improve its moisture resistance. The sensing elements multilayer construction also provides excellent resistance in applications where dust, dirt, oils and common environmental chemicals are found. The RH room sensors include on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources.

Applications

Humidification, Dehumidification, Monitoring Indoor Space Humidity, Clean Rooms, Hospitals, Process Control, Laboratories, Museums, Schools, Office Buildings, Data Centers, ESD (Anti-Static) Control
 

RH Supply Voltage (Reverse Polarity Protected): 4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC
500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC
0-5 VDC: 12 - 40 VDC / 18 - 28 VAC
0-10 VDC: 18 - 40 VDC / 18 - 28 VAC
RH Supply Current (VA): Voltage Output: 8 mA max (0.32 VA) | Current Output: 24 mA max (0.83 VA)
RH Output Load Resistance: 4-20 mA: 700 Ohms max | 0-5 VDC or 0-10 VDC: 4K Ohms min
RH Output Signal: 2-wire: 4 - 20 mA (default) | 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable)
RH Accuracy @ 77°F (25°C): +/- 1% over 20% RH Range between 20 to 90% | +/- 2%, 3%, or 5% from 10 to 95%
RH Measurement Range: 0-100%
Operating RH Range: 0 to 95% RH, non-condensing (Conformally Coated PCB's)
Operating Temperature Range: 35 to 122°F (1.5 to 60°C)
Storage Temperature Range: -40 to 149°F (-40 to 65°C)
RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH
RH Response Time (T63): 20 Seconds Typical
RH Sensor Type: Capacitive with Hydrophobic Filter
RH Transmitter Stabilization Time: 30 Minutes (Recommended time before doing accuracy verification)
RH Connections | Wire Size: Screw Terminal Blocks (Polarity Sensitive) | 16 (1.31 mm²) to 26 AWG (0.129 mm²)
RH Terminal Block Torque Rating: 4.43 to 5.31 lb-in (0.5 to 0.6 Nm)
RH NIST Test Points: Default Test Points: 3 Pts (20%, 50% & 80%) or 5 Pts (20%, 35%, 50%, 65% & 80%)
1% NIST Test Points: 5 Pts within selected 20% Range (ie. 30%-50% are 30, 35, 40, 45 & 50)
Nominal Thermistor Resistive Output @ 77°F (25°C) | Lead Wire Colors: 10KΩ | White/Green
Thermistor Accuracy 32-158°F (0-70°C): +/- 0.36°F (0.2°C)
Thermistor Power Dissipation Constant: 3 mW/°C
Thermistor Sensor Response Time (T63): 10 Seconds nominal
Temperature Connections | Wire Size: Screw Terminal Blocks (Polarity Sensitive) | 16 (1.31 mm²) to 26 AWG (0.129 mm²)
Temp Terminal Block Torque Rating: 4.43 to 5.31 lb-in (0.5 to 0.6 Nm)
Enclosure Material (Color): ABS (White)
Enclosure Flammability Rating: UL94-HB
Product Dimensions (L x W x D): 4.50'' (114.3 mm) x 2.75'' (69.85 mm) x 1.12'' (28.45 mm)
Product Weight: 0.17 lbs. (0.077 kg)
Agency Approvals: CE, RoHS2, WEEE

More detail about United Faith Sdn Bhd
United Faith Sdn Bhd
United Faith Sdn Bhd Air Conditioner Parts Supplier Selangor, Air Cond Services Kuala Lumpur (KL), Refrigeration Tools Malaysia, Singapore ~ United Faith Sdn Bhd
Contact Us flagMalaysia