UNIPULSE – Digital Indicator (F331)

UNIPULSE – Digital Indicator (F331)

Category: Weighing Available
For more information, visit our official website at carlssoon-tech.com

Description

UNIPULSE – Digital Indicator
Brand: Unipulse
Model: F331
 
Product Outline:
F331 is a digital indicator for strain gauge sensors to measure load, torque, pressure and displacement. Compact and simple configuration, a practical machine with features such as hold and judgment.

Features:

Specifications:

Analog Sensor excitation voltage DC2.5V±10% Output current within 30mA : Standard specification 5V spec. (Please specify when ordering.)
(DC5V±10% Output current within 30mA)
Signal input range -3.0 to +3.0mV/V
Equivalent input calibration range +0.5 to +3.0mV/V
Equivalent input calibration error Within 0.1%FS(at 0.5mV/V input)
Accuracy Non-linearity: Within 0.02%/FS(at 3mV/V input)
Zero drift: Within 0.5μV/℃ RTI
Gain drift: Within 0.01%/℃
A/D converter Rate: 300 times/sec.
Resolution: 24 bits (binary)
Hold function Sample, Peak, Bottom, P-P
  Display Character height 14.2mm Numerical display (4-digits), by 7-segment red LED
Indicated value Numeric 4-digits -9999 to 9999 (Minus is a most significant digit. It display at the status lamp.)
Decimal point The display position is selectable. (8.888、88.88、888.8、8888)
Display items Status display
3φ red LED ×2 (MINUS, HOLD)
3φ green LED ×1 (OK)
Display frequency 5, 10, 20 times/sec. selectable
Setting Section Setting method Setting by specific PC software with USB interface.
Preservation of data Stored in nonvolatile RAM (NOVRAM)
Key switch ZERO
Setting items Calibration: Zero calibration/ Span calibration (actual load calibration, equivalent input calibration)
HH limit, HI limit, LO limit, LL limit, Hysteresis, Digital offset, Near zero, Comparison timing, Moving average filter, Digital low-pass filter*, Hold mode, ZERO key valid/invalid, Display frequency, Decimal place, External output selection, Indicator ID, Loadcell ID, BCD output mode, BCD data update rate, BCD output selection, D/A output mode, D/A zero scale, D/A full scale, RS-485 communication mode, RS-485 I/F setting, RS-485 ID, RS-485 transmission delay time, RS-232C communication mode, RS-232C I/F setting, Setting value LOCK (485/232), Calibration value LOCK (485/232)
※3, 6, 12Hz selectable
 
For more information please click the link for reference: https://www.unipulse.tokyo/en/product/f331/