Gemini® Packaged Air-Handling Unit 40RUQ Heat Pump, with Puron® Refrigerant (R-410A) 6 to 20 Tons

Gemini® Packaged Air-Handling Unit 40RUQ Heat Pump, with Puron® Refrigerant (R-410A) 6 to 20 Tons

Category: Carrier Available
For more information, visit our official website at unitedfaith.com.my

Description

Heat Pump, with Puron® Refrigerant (R-410A)

6 to 20 Tons

The Gemini® 40RU and 38AU series indoor air handlers and outdoor units provide a wide variety of options for your HVAC application needs. These units are designed for long dependable operation whether it’s a rooftop or on-the-ground installation. All Gemini® 38AU Condensing Units and 40RU Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.

The 40RU series indoor air handler contains a chilled water coil and may be interfaced into chilled water systems. The 40RU series has a multi-position design that allows for vertical or horizontal installation with no modifications. Powerful fan systems allow easy adaptation to existing ductwork. For heating capability, the 40RU’s allow for field installed electric heaters, hot water coils, or steam coils.


carrier-AHRI-340-360-Unitary-Large-AC
carrier-intertek-ETL-listed-C-US

Performance Features

Reliability Features

Installation Features

Maintenance Features


Factory-Installed Options

  • Unit voltage options:
    • 208/230-3-60
    • 460-3-60
    • 575-3-60
    • 208/230-1-60 (sizes 07 and 08)
  • Staged Air Volume (SAV) Indoor Fan Speed System (sizes 12-25)
  • Alternate fan motors
  • Medium and high-static drives
  • Pre-painted units

Field-Installed Accessories

  • Outside air enthalpy controlled economizer
  • Electric heater
  • Hot water heating coils
  • Steam heating coil
  • Programmable thermostats
  • CO2 sensors
  • Airflow sensor switch
  • Painted and non-painted options:
    • Discharge plenum
    • Return air grille
    • Floor mount subbase
  • Condensate overflow switch assembly
  • Overhead suspension package

38AUQ/40RUQ AHRI Cooling Ratings

Unit Cooling Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) EER IEER
38AUQ07/40RUQ07 1 6 70.0 6.4 11.0 12.6
38AUQ08/40RUQ08 1 7.5 89.0 8.1 11.0 12.0
38AUQ12/40RUQ12 1 10 112.0 10.2 11.0 12.0
38AUQ16/40RUQ16 2 15 178.0 16.8 10.6 11.0
38AUQ25/40RUQ25 2 20 222.0 20.8 10.7 11.0

38AUQ/40RUQ AHRI High Heat Ratings at 47°F (8°C)

Unit Heating Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) COP
38AUQ07/40RUQ07 1 6 66.0 5.9 3.30
38AUQ08/40RUQ08 1 7.5 87.0 7.7 3.30
38AUQ12/40RUQ12 1 10 106.0 9.4 3.30
38AUQ16/40RUQ16 2 15 178.0 15.3 3.40
38AUQ25/40RUQ25 2 20 214.0 17.9 3.50

38AUQ/40RUQ AHRI Low Heat Ratings at 17°F (-8°C)

Unit Heating Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) COP
38AUQ07/40RUQ07 1 6 39.0 5.2 2.20
38AUQ08/40RUQ08 1 7.5 52.0 6.9 2.20
38AUQ12/40RUQ12 1 10 70.0 9.3 2.20
38AUQ16/40RUQ16 2 15 108.0 13.2 4.40
38AUQ25/40RUQ25 2 20 130.0 15.9 2.40

AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance

NOTES
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
-Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
-IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.

More detail about United Faith Sdn Bhd
United Faith Sdn Bhd
United Faith Sdn Bhd Air Conditioner Parts Supplier Selangor, Air Cond Services Kuala Lumpur (KL), Refrigeration Tools Malaysia, Singapore ~ United Faith Sdn Bhd
Contact Us flagMalaysia