Safe series connection: None, only individual wiring (with diagnostics)
Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs)
Features
System part
Sensor and actuator
Sensor principle
Transponder
Number of safe outputs
2
Auxiliary contact (AUX)
1 (Switching behavior complementary to OSSDs)
Safe switch on distance Sao
10 mm (–30 °C ... +70 °C) 1)
Safe switch off distance Sar
25 mm 1)
Active sensor surfaces
3
Actuation directions
5
Coding
Uniquely coded
1) Values apply for the frontal alignment of the sensor to the actuator. A detailed display of the alignment options and values can be found in the operating instructions.
Technical drawings
Dimensional drawing Sensor with cable
Dimensional drawing ''Standard'' actuator
Response range ''Standard'' actuator, active front sensor surface
Response range ''Standard'' actuator, active side sensor surface